background image

630 Series

4

!

WaRnIng

To avoid the consequences of over-

tightening the spring in spring-loaded 

regulators or relief valves, consult 

Table 4 and replace the adjusting screw 

with one of the correct length when 

replacing the spring.

Some pressure ratings are dependent upon the actual 

outlet pressure settings being used. For example, 

with a Type 630 regulator, outlet pressure must not 

exceed the setting by more than 20 psig / 1.38 bar 

for low pressure constructions or 200 psig / 13.8 bar 

for high pressure constructions or damage to internal 

regulator parts may occur. However, with some higher 

pressure ranges, the setting plus 20 psig / 1.38 bar or 

200 psig / 13.8 bar exceeds the maximum emergency 

outlet (casing) pressure. Before increasing the setting, 

refer to Tables 2 and 3 (as appropriate). Review the 

pressure limits for the spring range being used and 

be certain that the new pressure setting will not result 

in an overpressure condition. Always use a pressure 

gauge to monitor pressure when making adjustments.

adjusting Spring-loaded Regulators 

and Relief Valves

Loosen the hex nut (key 2, Figures 4, 5 and 6) atop 

the spring case. While monitoring the pressure, 

rotate the adjusting screw (key 1, Figures 4, 5 and 6) 

clockwise to increase set pressure or counterclockwise 

to decrease it. When the unit is regulating or relieving 

pressure at the desired value, tighten the hex nut.

Shutdown

Slowly close the upstream block valve.

Principle of Operation

This section describes the operation of the Type 630 

regulator and the Type 630R relief valve with spring 

loading. Set pressure is changed with the adjusting 

screw on the regulator or relief valve. The Type 630R 

relief valve uses a light spring for added stability.

Type 630 Regulators

Refer to Figure 2. In the regulator construction, outlet 

pressure registers beneath the diaphragm. As long 

as the outlet pressure is less than the set pressure, 

spring force on the diaphragm causes the lever to hold 

46A2977

A2526-1

Figure 3.

 Type 630R Relief Valve Operational Schematic

46A2976-A

A2525-1

Figure 2.

 Type 630 Regulator Operational Schematic

aTMOSPHERIC PRESSURE

OUTlET PRESSURE

InlET PRESSURE

aTMOSPHERIC PRESSURE

OUTlET PRESSURE

InlET PRESSURE

Summary of Contents for Fisher 630 Series

Page 1: ...or is installed where service conditions could exceed the limits given in Specifications section Tables 1 through 3 or where conditions exceed any ratings of the adjacent piping or piping connections To avoid such injury or damage provide pressure relieving or pressure limiting devices as required by the appropriate code regulation or standard to prevent service conditions from exceeding those lim...

Page 2: ...caping gas may accumulate and be an explosion hazard Under these conditions the vent should be piped away from the unit to a freely ventilated outdoor location away from air intakes windows etc Protect all vent openings against weather or the entrance of any foreign material that may plug the vent or affect operation of the regulator or relief valve Inspect all vent openings periodically to be sur...

Page 3: ...Setting Plus Maximum Allowable Buildup of 250 psig 17 2 bar 550 37 9 1 Leakage or bursting of pressure containing parts may occur if inlet pressure exceeds these values To avoid overpressure provide an appropriate overpressure protection device to ensure that none of the limits listed in Specifications section Tables 1 through 3 will be exceeded Regulator or relief valve operation below the limits...

Page 4: ...king adjustments Adjusting Spring Loaded Regulators and Relief Valves Loosen the hex nut key 2 Figures 4 5 and 6 atop the spring case While monitoring the pressure rotate the adjusting screw key 1 Figures 4 5 and 6 clockwise to increase set pressure or counterclockwise to decrease it When the unit is regulating or relieving pressure at the desired value tighten the hex nut Shutdown Slowly close th...

Page 5: ...ice key 20 and the Type 630R valve seat O ring key 37 Figure 6 caution If step 1 is omitted and the body and inlet adaptor are separated take care to avoid pinching fingers between the body and the inlet adaptor 1 Disconnect piping from inlet adaptor key 18 Remove four cap screws key 17 and adaptor 2 Remove orifice key 20 and gaskets key 19 3 To remove Type 630 valve disk key 21 Figures 4 and 5 or...

Page 6: ...screwing cap screws and nuts keys 9 10 and 30 4 Remove diaphragm key 11 and attached parts from the lever key 14 5 Unscrew cap screw key 6 from connector head assembly key 12 and disassemble the diaphragm assembly 6 Install new diaphragm being certain that the diaphragm is centered Note that low pressure constructions use a diaphragm plate key 8 Figure 5 on the spring case side of the diaphragm In...

Page 7: ...in the following parts list Separate kit containing all recommended spare parts is available Parts List Note In this parts list parts marked NACE are intended for corrosion resistant service as detailed in the NACE International Standard MR0175 Parts Kits Type 630 regulator kits are for low or high pressure spring loaded construction Kits include neoprene diaphragm copper inlet gasket material for...

Page 8: ...0X000H52 Stainless steel PTFE R630X000H62 Key Description Part Number High Pressure continued With orifice key 20 1 8 in 3 18 mm Brass Nylon PA R630X000HC2 1 8 in 3 18 mm Stainless steel Nylon PA standard R630X000HD2 1 8 in 3 18 mm Stainless steel Nylon PA NACE R630X00NHD2 1 4 in 6 35 mm Brass Nylon PA R630X000HA2 1 4 in 6 35 mm Stainless steel Nylon PA standard R630X000HB2 1 4 in 6 35 mm Stainles...

Page 9: ...6985X0072 High pressure Cast iron 0W019819012 Steel 2N698722012 Steel NACE 2N6987X0042 14 Lever Assembly Steel or Stainless steel Low pressure 1B2891000A2 Low pressure NACE 1B2891X0032 High pressure 1B2890000A2 High pressure NACE 1B2890X0022 Key Description Part Number 15 Pin Stainless steel 0W018835172 Stainless steel NACE 0W0188X0022 16 Gasket Composition 0W018704022 17 Cap Screw steel 4 require...

Page 10: ...1 NPT 0W0209000A2 2 NPT 0W021519012 Steel 1 NPT 2N6990000A2 1 NPT NACE 2N6990X0092 2 NPT 2N699122012 2 NPT NACE 2N6991X0032 CL150 RF 1 in DN 25 27B3333X012 2 in DN 50 27B3336X012 2 in DN 50 Type 630R only 28B6244X012 CL300 RF 1 in DN 25 27B3334X012 2 in DN 50 27B3337X012 2 in DN 50 Type 630R only 28B6245X012 CL600 RF 1 in DN 25 27B3335X012 2 in DN 50 27B3338X012 2 in DN 50 Type 630R only 28B6246X0...

Page 11: ...or Code psig bar Spring Loaded Type 630 Low Pressure 3 to 10 8 to 20 17 to 30 27 to 40 0 21 to 0 69 0 55 to 1 38 1 17 to 2 07 1 86 to 2 76 0W019227022 0W019127022 0W019027022 0Y066427022 Red Stripe Olive Drab Silver Green Stripe High Pressure 27 to 50 46 to 95 90 to 150 150 to 200 200 to 275 275 to 500 1 86 to 3 45 3 17 to 6 55 6 21 to 10 3 10 3 to 13 8 13 8 to 19 0 19 0 to 34 5 0W019227022 0W0191...

Page 12: ...intenance of any Emerson Process Management Regulator Technologies Inc product remains solely with the purchaser Industrial Regulators Emerson Process Management Regulator Technologies Inc USA Headquarters McKinney Texas 75070 USA Tel 1 800 558 5853 Outside U S 1 972 548 3574 Asia Pacific Shanghai 201206 China Tel 86 21 2892 9000 Europe Bologna 40013 Italy Tel 39 051 419 0611 Middle East and Afric...