Instruction Manual
D200160X012
4195K Controllers
July 2018
6
Table 1‐1. Specifications (continued)
Housing
Designed to NEMA 3 (Weatherproof) and IEC 529
IP54 Specifications
Mounting
Controller can be mounted on actuator, panel, wall,
or pipestand.
Approximate Weight
4.5 kg (10 pounds)
Declaration of SEP
Fisher Controls International LLC declares this
product to be in compliance with Article 4 paragraph
3 of the PED Directive 2014/68/EU. It was designed
and manufactured in accordance with Sound
Engineering Practice (SEP) and cannot bear the CE
marking related to PED compliance.
However, the product
may
bear the CE marking to
indicate compliance with
other
applicable EC
Directives.
NOTE: Specialized instrument terms are defined in ANSI/ISA Standard 51.1 - Process Instrument Terminology.
1. Consult your
or Local Business Partner for additional information.
2. The pressure/temperature limits in this document and any applicable standard or code limitation should not be exceeded.
3. Normal m
3
/hr—Normal cubic meters per hour (0
_
C and 1.01325 bar, absolute). Scfh—Standard cubic feet per hour (60
_
F and 14.7 psia).
4. Without auto/manual station. With auto/manual station add 0.01 m
3
/hr (0.5 scfh) for either output range.
5. Also use these temperatures for transportation and storage limits.
Table 1‐2. Available Configurations for Fisher 4195KA, 4195KB, 4195KC, and 4195KS Controllers
CONTROLLER
TYPE
NUMBER
MODES
OPTIONS
Proportional‐
Only
(One‐Mode
Controllers)
Proportional‐
Plus‐Reset
(Two‐Mode
Controllers)
Proportional‐
Plus‐Reset‐
Plus‐Rate
(Three‐Mode
Controllers)
Differential
Gap Controller
Internal
Auto/Manual
Station
E
Anti‐Reset
Windup
F
Remote
Setpoint
M
4195KA
4195KA
4195KAE
4195KAM
4195KAME
X
X
X
X
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
X
- - -
X
- - -
- - -
- - -
- - -
- - -
- - -
X
X
4195KB
4195KB
4195KBE
4195KBF
4195KBFE
4195KBM
4195KBME
4195KBFM
4195KBFME
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
X
X
X
X
X
X
X
X
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
X
- - -
X
- - -
X
- - -
X
- - -
- - -
X
X
- - -
- - -
X
X
- - -
- - -
- - -
- - -
X
X
X
X
4195KC
4195KC
4195KCE
4195KCF
4195KCFE
4195KCM
4195KCME
4195KCFM
4195KCFME
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
X
X
X
X
X
X
X
X
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
X
- - -
X
- - -
X
- - -
X
- - -
- - -
X
X
- - -
- - -
X
X
- - -
- - -
- - -
- - -
X
X
X
X
4195KS
4195KS
4195KSE
4195KSM
4195KSME
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
X
X
X
X
- - -
X
- - -
X
- - -
- - -
- - -
- - -
- - -
- - -
X
X
1. Reverse‐acting constructions are designated by the suffix letter R added to the type number.