Instruction Manual
D103296X012
2052 Actuator
June 2017
15
4. Insert a padlock (not furnished by Emerson Automation Solutions) to prevent the mounting plate assembly from
rotating.
To Unlock the Actuator
1. Remove the padlock. Loosen the jam nut (key 40), and unscrew the threaded bolt until it no longer protrudes inside
the housing.
Note
Ensure the mounting plate assembly bolt is unthreaded far enough that the actuator lever will not contact the bolt during normal
actuator operation.
2. If the mounting plate assembly is to be left partially threaded into the housing, lock it with the jam nut (key 40) so
that it cannot be screwed further into the housing and interfere with normal actuator operation.
Figure 6. Size 2 and 3 Locking Mechanism
PART ORIENTATION FOR SIZE 3 END-MOUNT INSTRUMENT
CUSTOMER SUPPLIED
LOCKING DEVICE
SIZE 3