background image

ES-805 and ES-905 Series Vent Valves

Table of Contents

Introduction ............................................................................1
Specifications ........................................................................2
Principle of Operation ............................................................2
Model Identification................................................................2
Installation .............................................................................2
Maintenance ..........................................................................5
V-ring Replacement ...............................................................6
Retrofit ES-805 and ES-905 Series Pallet Assembly ............6
Parts Ordering .......................................................................6
Parts List................................................................................7

!

WARNING

Failure to follow these instructions or to 

properly install and maintain this equipment 

could result in an explosion, fire and/or 

chemical contamination causing property 

damage and personal injury or death.
Enardo™ vent valves must be installed, 

operated and maintained in accordance 

with federal, state and local codes, rules 

and regulations and Emerson Process 

Management Regulator Technologies 

Tulsa, LLC instructions.
Failure to correct trouble could result in a 

hazardous condition. Call a qualified service 

person to service the unit. Installation, 

operation and maintenance procedures 

performed by unqualified person may result 

in improper adjustment and unsafe operation. 

Either condition may result in equipment 

damage or personal injury. Only a qualified 

person shall install or service the vent valves.

Introduction

Scope of the Manual

This Instruction Manual provides instructions for installation, 

maintenance and parts ordering guide for the ES-805 and 

ES-905 Series vent valves.

WARNING

!

The ES-805 and ES-905 Series vent valves is 

not necessarily grounded when installed on 

fiberglass reinforced plastic tanks unless the 

base is electrically bonded to the tank.

To avoid personal injury or property damage 

resulting from the effects of a static electricity 

discharge from hatch components in a 

hazardous atmosphere or where the process 

fluid is combustible, electrically bond the base 

to the tank with grounding strap.

Figure 1. Typical ES-805 Series In-Line Vent Valve

Figure 2. Typical ES-905 Series End-of-Line Vent Valve

Instruction Manual

D104466X012
April 2019

ES-805 and ES-905 Series

North America 

Only

Summary of Contents for ES-805 Series

Page 1: ...nance procedures performed by unqualified person may result in improper adjustment and unsafe operation Either condition may result in equipment damage or personal injury Only a qualified person shall install or service the vent valves Introduction Scope of the Manual This Instruction Manual provides instructions for installation maintenance and parts ordering guide for the ES 805 and ES 905 Serie...

Page 2: ...t they omit the vacuum side of the valve that eliminates the possibility of two way flow Model ES 905 SO is an end of line vent valve The end of line vent valve is installed directly on the end of the vent line exhaust The Model ES 905 SO has both pressure and vacuum relief capability Model ES 905 PSO is an end of line vent valve The end of line vent valve is installed directly on the end of the v...

Page 3: ... oz sq in 2 mbar increments 0 4 oz sq in 1 7 mbar ES 805 PSO N A ES 905 SO 0 4 oz sq in 1 7 mbar ES 905 PSO N A Table 1 Vent Setting Range MODEL HOUSING PALLET V RING SEAL HARDWARE WEIGHTS GASKETS ES 805 SO Cast Aluminum Aluminum Nitrile NBR or Fluorocarbon FKM Zinc plated carbon steel Zinc plated carbon steel to 12 oz sq in or Lead Nitrile NBR or Fluorocarbon FKM ES 805 PSO ES 905 SO ES 905 PSO T...

Page 4: ...e with the rib on the body Then close the lid and hand tighten the wing nuts on both sides Tools are not to be used to tighten wing nuts Check for proper alignment between the lid and pallet stem If the pallet is not installed correctly the lid would not close ES 905 Series End of Line Vent Valve 1 Unbolt and remove the flanges from the body 2 Slide the flange onto the receiving pipe Then slide th...

Page 5: ...pheres may require more frequent inspections and maintenance Always inspect the pressure and vacuum gaskets and all sealing surfaces when performing maintenance 1 Remove the pallet assembly from the valve Pull the vacuum disk down until it stops and release it If the vacuum disk does not return to the closed position clean the rods with a mild solvent and apply a graphite lubricant If cleaning doe...

Page 6: ...able 5 Parts Ordering When corresponding with your local Sales Office about this equipment always reference the equipment serial number and model number that can be found etched on the nameplate When ordering replacement parts specify the complete model number and 7 character part number of each required part as found in the following parts list MATERIAL 2 IN 50 mm 3 IN 80 mm 4 IN 100 mm Nitrile N...

Page 7: ...14318 4 in 100 mm 3514365 Fluorocarbon FKM 2 in 50 mm 3514314 3 in 80 mm 3514319 4 in 100 mm 3514372 15 Nylock Nut 1 2 13 16 Pressure Weight as required ES 905 Series In line Vent Valve Key Description Part Number 1 Valve Body 2 in 50 mm 3514326 3 in 80 mm 3514337 4 in 100 mm 3514341 2 Hood 2 in 50 mm 3514329 3 in 80 mm 3514339 4 in 100 mm 3514343 3 Flange Gasket 2 in 50 mm 3505501 3 in 80 mm 3505...

Page 8: ...erson logo is a trademark and service mark of Emerson Electric Co All other marks are the property of their prospective owners Enardo is a mark owned by Regulator Technologies Tulsa LLC a business of Emerson Automation Solutions The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warran...