V-ring Replacement

!

WARNING

Ensure the tank is at atmospheric pressure 

before opening. A pressure build-up inside the 

tank can cause a spray to be emitted from the 

vent valve if opened under pressure.

1.  Remove the pallet assembly. Grasp the pressure seal 

firmly by the lip and pull out.

2. 

Insert the new seal. Use a finger, wrench or other 

smooth edge to apply a firm pressure while sliding 

around the entire seal several times. When the seal is 

completely seated, there will be no humps or waves in 

the lip.

Retrofit ES-805 and ES-905 Series 

Pallet Assembly

!

WARNING

Ensure the tank is at atmospheric pressure 

before opening. A pressure build-up inside the 

tank can cause a spray to be emitted from the 

vent valve if opened under pressure.

The legacy ES-800 and ES-900 Series valve can be 

upgraded to an ES-805/ES-905 Series by replacing the 

existing pallet assembly with the new ES-805/ES-905 Series 

pallet assembly.

Retrofit kits that include a new ES-805/ES-905 Series pallet 

assembly, V-ring seal and nameplate are available. Follow 

the instructions outlined in the Maintenance section of this 

manual for removal and replacement of pallet assembly and 

V-ring seal. Part numbers for ES-805/ES-905 Series retrofit 

kits can be found in Table 5.

Parts Ordering

When corresponding with your local Sales Office about 

this equipment, always reference the equipment serial 

number and model number that can be found etched on 

the nameplate.
When ordering replacement parts, specify the complete 

model number and 7-character part number of each required 

part as found in the following parts list.

MATERIAL

2 IN. / 50 

mm

3 IN. / 80 

mm

4 IN. / 100 

mm

Nitrile (NBR)

3514286

3514316

3514323

Fluorocarbon (FKM)

3514313

3514317

3514324

Table 4. V-ring Seal - Pressure Seal Options

MODEL

MATERIAL

2 IN. / 50 

mm

3 IN. / 80 

mm

4 IN. / 100 

mm

ES-805-SO or ES-905-SO

Nitrile (NBR)

ERAA43150A0

ERAA43150A2

ERAA43150A4

Fluorocarbon (FKM)

ERAA43150A1

ERAA43150A3

ERAA43150A5

ES-805-PSO or ES-905-PSO

- - - -

3514268

3514294

3514333

Table 3. Pallet Assembly Options

SERIES

SIZE

MATERIAL

PART NUMBER

Convert from

Convert to

ES-820/ES-920

ES-825/ES-925

2 in. / 50 mm

Nitrile (NBR) (Buna)

3514826

Fluorocarbon (FKM) (Viton

®

)

3514832

ES-830/ES-930

ES-835/ES-935

3 in. / 80 mm

Nitrile (NBR) (Buna)

3514828

Fluorocarbon (FKM) (Viton

®

)

3514829

ES-840/ES-940

ES-845/ES-945

4 in. / 100 mm

Nitrile (NBR) (Buna)

3514830

Fluorocarbon (FKM) (Viton

®

)

3514831

Note:  Convert existing ES-800 and ES-900 Series valves by installing these parts. Kit includes ES-805/ES-905 Series pallet assembly, new V-ring pressure seal and new ES-805/

ES-905 Series nameplate.

Table 5. Retrofit Kits

Viton

®

 is a mark owned by E.I. du Pont de Nemours and Co.

6

ES-805 and ES-905 Series

North America 

Only

Summary of Contents for ES-805 Series

Page 1: ...nance procedures performed by unqualified person may result in improper adjustment and unsafe operation Either condition may result in equipment damage or personal injury Only a qualified person shall install or service the vent valves Introduction Scope of the Manual This Instruction Manual provides instructions for installation maintenance and parts ordering guide for the ES 805 and ES 905 Serie...

Page 2: ...t they omit the vacuum side of the valve that eliminates the possibility of two way flow Model ES 905 SO is an end of line vent valve The end of line vent valve is installed directly on the end of the vent line exhaust The Model ES 905 SO has both pressure and vacuum relief capability Model ES 905 PSO is an end of line vent valve The end of line vent valve is installed directly on the end of the v...

Page 3: ... oz sq in 2 mbar increments 0 4 oz sq in 1 7 mbar ES 805 PSO N A ES 905 SO 0 4 oz sq in 1 7 mbar ES 905 PSO N A Table 1 Vent Setting Range MODEL HOUSING PALLET V RING SEAL HARDWARE WEIGHTS GASKETS ES 805 SO Cast Aluminum Aluminum Nitrile NBR or Fluorocarbon FKM Zinc plated carbon steel Zinc plated carbon steel to 12 oz sq in or Lead Nitrile NBR or Fluorocarbon FKM ES 805 PSO ES 905 SO ES 905 PSO T...

Page 4: ...e with the rib on the body Then close the lid and hand tighten the wing nuts on both sides Tools are not to be used to tighten wing nuts Check for proper alignment between the lid and pallet stem If the pallet is not installed correctly the lid would not close ES 905 Series End of Line Vent Valve 1 Unbolt and remove the flanges from the body 2 Slide the flange onto the receiving pipe Then slide th...

Page 5: ...pheres may require more frequent inspections and maintenance Always inspect the pressure and vacuum gaskets and all sealing surfaces when performing maintenance 1 Remove the pallet assembly from the valve Pull the vacuum disk down until it stops and release it If the vacuum disk does not return to the closed position clean the rods with a mild solvent and apply a graphite lubricant If cleaning doe...

Page 6: ...able 5 Parts Ordering When corresponding with your local Sales Office about this equipment always reference the equipment serial number and model number that can be found etched on the nameplate When ordering replacement parts specify the complete model number and 7 character part number of each required part as found in the following parts list MATERIAL 2 IN 50 mm 3 IN 80 mm 4 IN 100 mm Nitrile N...

Page 7: ...14318 4 in 100 mm 3514365 Fluorocarbon FKM 2 in 50 mm 3514314 3 in 80 mm 3514319 4 in 100 mm 3514372 15 Nylock Nut 1 2 13 16 Pressure Weight as required ES 905 Series In line Vent Valve Key Description Part Number 1 Valve Body 2 in 50 mm 3514326 3 in 80 mm 3514337 4 in 100 mm 3514341 2 Hood 2 in 50 mm 3514329 3 in 80 mm 3514339 4 in 100 mm 3514343 3 Flange Gasket 2 in 50 mm 3505501 3 in 80 mm 3505...

Page 8: ...erson logo is a trademark and service mark of Emerson Electric Co All other marks are the property of their prospective owners Enardo is a mark owned by Regulator Technologies Tulsa LLC a business of Emerson Automation Solutions The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warran...

Reviews: