6
EN-DFA Series
North America
Only
Table 6.
Temperature Sensor Safety Specifications
TECHNICAL DATA
THERMOCOUPLE
Design Type
Standard
with thermowell
Standard
without thermowell
Model
185 03J1
Code 0185 thermocouple (IEC 584 Class 1) without thermowell
Manufacturer
Emerson Rosemount
Emerson Rosemount
EC-Type Approval Certificate
FM12ATEX0065X
ATEX: EN 60079-0:2012+A11:2013; EN 60079-1: 2014
FM12ATEX0065X
ATEX: EN 60079-0:2012+A11:2013; EN 60079-1: 2014
Temperature Sensor Design
Type-K thermocouple
Type-K thermocouple
Type of Ignition Protection
II 2 G Ex d IIC T6...T1 Gb, T6(–50°C ≤ Ta ≤ + 40°C), T5...
T1 (–50°C ≤ Ta ≤ + 60°C)
II 2 G Ex d IIC T6...T1 Gb, T6(–50°C ≤ Ta ≤ + 40°C), T5...
T1 (–50°C ≤ Ta ≤ + 60°C)
Protection Type (Connection Head)
Rosemount Aluminum
Explosion proof, 2-wire, 3-wire, 4-wire type A, 4-Wire type as specified
by customer
Intrinsically safe option is available
Rosemount Aluminum
Explosion proof, 2-wire, 3-wire, 4-wire type A, 4-Wire type as specified
by customer
Intrinsically safe option is available
Measuring Probe (Measuring Insert)
1/2 MPT or optional M24 x1.5. Intended for installation into thermowell.
1/2 MPT. Intended for installation without thermowell.
Connection Thread
1/2 MPT. Intended for installation into thermowell
1/2 MPT. Intended for installation without thermowell.
Transmitter
Optional by customer request
Optional by customer request
Intended Application
In-line flame arrestors and detonation arrestors
End-of-line flame arrestors. Free-vent style.
TECHNICAL DATA
THERMOCOUPLE
Design Type
Standard
with thermowell
Standard
without thermowell
Model
TC 10-2 (for additional Thermowell)
TC10-H (threaded for direct insertion without thermowell)
Manufacturer
WIKA
WIKA
EC-Type Approval Certificate
ATEX and IECEx certifications
ATEX and IECEx certifications
Temperature Sensor Design
Type-K thermocouple
Type-K thermocouple
Type of Ignition Protection
II 2 G Ex d IIC T6...T1 Gb, T6(–50°C ≤ Ta ≤ + 40°C), T5...
T1 (–50°C ≤ Ta ≤ + 60°C)
II 2 G Ex d IIC T6...T1 Gb, T6(–50°C ≤ Ta ≤ + 40°C), T5...
T1 (–50°C ≤ Ta ≤ + 60 °C)
Protection Type (Connection Head)
Explosion proof, 2-wire, 3-wire, 4-wire type A, 4-Wire type as specified
by customer.
Intrinsically safe option is available .
Explosion proof, 2-wire, 3-wire, 4-wire type A, 4-Wire type as specified
by customer.
Intrinsically safe option is available.
Measuring Probe (Measuring Insert)
Spring loaded plate
Probe allows use of transmitter.
Length varies by flame arrestor size.
Probe length varies by flame arrestor size.
Adjustable insertion length.
Connection Thread
1/2 MPT or optional M24 x1.5. Intended for installation into thermowell.
1/2 MPT. Intended for installation without thermowell.
Transmitter
Optional by customer request
Optional by customer request
Intended Application
In-line flame arrestors and detonation arrestors
End-of-line flame arrestors. Free-vent style.
Table 7.
Torque Values for Raised Face Connection Flange (Steel Only)
NOMINAL PIPE DIAMETER
NUMBER OF BOLTS
BOLT DIAMETER
TORQUE
In.
mm
Ft-lb
N•m
1
4
0.50
12.70
9
12.20
1-1/4
4
0.50
12.70
13
17.63
1-1/2
4
0.50
12.70
18
24.40
2
4
0.63
16.00
35
47.45
2-1/2
4
0.63
16.00
41
55.59
3
4
0.63
16.00
60
81.35
3-1/2
8
0.63
16.00
34
46.10
4
8
0.63
16.00
43
58.30
6
8
0.75
19.05
80
108.5
8
8
0.75
19.05
109
147.8
10
12
0.88
22.4
101
136.9
12
12
0.88
22.4
135
183.0
Assumptions: Use of SAE grade 5 bolts or studs or stronger
No lubricant
Compressed mineral fiber material or similar
Notes: If lubricant is used on bolts, apply torque reduction factor listed in Lubricant Table. For best results hardened steel washers should be used on all cast flange bolted connections.