background image

0508082120/101203/C

Page 3

Owner’s manual

Important Safety Instructions

Important Safety Instructions

Read and save these instructions

ATTENTION

Please read instructions before installing and using the air 
cleaner. This will help you obtain the full benefit from the air 
cleaner you have selected. 

A Read the Owner’s Manual and Important Safety Instructions 

carefully. Failure to follow these instructions could cause a 
malfunction of the filter or unsatisfactory service. 

B Follow a regular service and maintenance schedule for 

efficient operation. 

To reduce the risk of electric shock, fire and injury to persons:

• Do not use the air cleaner in wet or damp locations.
• The air cleaner is not for use in cooking areas.
• Do not use the air cleaner with any solid state speed control 

device.

• Do not use the air cleaner outdoors.
• Do not use the air cleaner at ambient temperatures above 

95°F/35°C. 

Mounting/installation

Please follow the installation instructions carefully.

Disconnect power prior to installing the air cleaner.

To reduce the risk of electric shock this equipment has a 
grounding type plug that has a third (grounding) pin. This plug 
will only fit into a grounding type power outlet.
If the plug does not fit into the outlet contact qualified 
personnel to install the proper outlet. Do not alter the plug in 
any way.

Use common sense, stay vigilant and pay attention to your 
actions during installation. Do not install the air cleaner when 
tired or affected by drugs, alcohol, medicines or otherwise 
impaired.

Use only screws delivered in the installation kit. Using other 
screws may damage the air cleaner and can cause a risk of 
shock, fire or injury to persons.

Do not use excessive strength to fasten the screws of the 
mounting assembly accessories. It will damage the air cleaner 
or mounts causing the air cleaner to fall. 
Do not remove a wall mounted air cleaner once it is installed.
Take special care when cleaning a wall mounted air cleaner.
Only use the special mounting kit for recessed ceiling mounted 
air cleaners.
Do not use the frame of the recessed ceiling to carry the weight 
of the air cleaner.

Fire hazard

Never use the air cleaner in areas with flammable gasses.

Never use the air cleaner to extract and/or filter flammable, 
smoldering or burning material.

Never use the air cleaner to extract and/or filter toxic fumes or 
abrasive particles.
Do not place any objects on top of the air cleaner.
Do not use with a damaged cord or plug.

Do not pull the cord to remove the plug from the mains. Protect 
the cord against heat, oil and sharp objects. Do not run any 
appliance over the cord. To unplug, grasp the plug, not the 
cord. Do not pull or carry by cord, use cord as a handle, close 
a door on cord, or pull cord around sharp edges or corners.
Do not move the air cleaner without having it unplugged first.

WARNING

ELECTROCUTION HAZARD.

Disconnect mains before servicing. Failure to do so 
could result in serious personal injury or death. 

WARNING

Do not attempt installation of this unit unless you are familiar with 
the necessary tools, equipment, utility connections and potential 
hazards. 
Installation should be performed only by a qualified service provider. 
Failure to do so could result in reduced performance of the unit, 
serious personal injury or death.

CAUTION

CELLS MAY CONTAIN SHARP EDGES.

Use care when servicing unit or handling cells. Failure 
to do so could result in minor personal injury.

WARNING

Installation of this unit must comply with local electric codes or other 
applicable codes. 
Review and understand local codes prior to installation. 
Do not use this apparatus in a flammable or explosive atmosphere. 
Failure to do so could result in serious personal injury or death. 

!

!

!

!

Summary of Contents for ECD1500

Page 1: ...MCD1200W MCD1200B Electronic Air Cleaner Épurateur d air Électronique ECS750W ECS750B ECD1500W ECD1500B 2SD1 Electrostatic Air Cleaner 2SD2 Electric Fan OWNER S MANUAL MANUEL OPÉRATEUR White Rodgers is a division of Emerson Electric Co www white rodgers com ...

Page 2: ... Cabinet Air Flow Color MCS600W MC Media Cleaner S Single Cabinet 600 Maximum Air Flow CFM W White MCS600B B Bronze MCD1200W D Double Cabinet 1200 Maximum Air Flow CFM W White MCD1200B B Bronze ECS750W EC Electronic Cleaner S Single Cabinet 750 Maximum Air Flow CFM W White ECS750B B Bronze ECD1500W D Double Cabinet 1500 Maximum Air Flow CFM W White ECD1500B B Bronze ...

Page 3: ...he outside of the air cleaner 3 5 CONTROL 4 5 1 Controlling with the panel button 4 5 2 Remote Control operation 4 5 3 Automatic operation auto mode 4 6 PROGRAM SETTINGS 4 6 1 Program Setting 1 Service Indicator 4 6 2 Program Setting 2 Resetting the Service Indicator 4 7 TROUBLESHOOTING 5 TECHNICAL REPAIR GUIDE 6 8 ADJUSTING TO SPECIFIC ROOM CONDITIONS 6 9 FILTER REPLACEMENT CLEANING 7 9 1 Prefilt...

Page 4: ...essories It will damage the air cleaner or mounts causing the air cleaner to fall Do not remove a wall mounted air cleaner once it is installed Take special care when cleaning a wall mounted air cleaner Only use the special mounting kit for recessed ceiling mounted air cleaners Do not use the frame of the recessed ceiling to carry the weight of the air cleaner Fire hazard Never use the air cleaner...

Page 5: ...kits Ensure that the load capacity of the mounting devices is sufficient to safely support the air cleaner The weights of the air cleaner are maximum 39 9 lbs and 65 5 lbs respectively For the single air cleaner on a pedestal use pedestal installation kit F848 0384 Use the materials prescribed during the installation Connect the air cleaner to power only after complete installation 4 MAINTENANCE M...

Page 6: ...llowing program settings allow you to customize the air cleaner operation for your personal preference Program Setting 1 Service Indicator Program Setting 2 Resetting the Service Indicator PROGRAM press this button once to get in the program mode While in the program mode if no key is pressed for 60 seconds the air cleaner will return to the last setting without saving any changes 6 1 Program Sett...

Page 7: ...in the cell for over 60 seconds the STANDBY led flashes Power will be interrupted to the cell s for 10 minutes which may allow the cause of the problem e g hair to flow out of the collecting cell After 10 minutes the high voltage will return to the cell If there is still a short in the cell the high voltage will again be interrupted for 10 minutes etc This loop stops at the fourth time a dead shor...

Page 8: ...will light up meaning you have set the pollution level to EXTREME DUTY If you want to go back to one of the previous pollution levels press W Press PROGRAM to confirm setting 1 and to go to setting 2 Program Setting 2 Resetting the Service Indicator The indicator needs to be reset when the media filter is changed out If led and led are flashing it is time to change the filter s and to reset the in...

Page 9: ...e of no high voltage to 120 minutes Press V led TURBO will light up meaning you ve set the time of no high voltage to 240 minutes If you want to go back to one of the previous time setting levels press W Press PROGRAM to confirm setting 8 The air cleaner will return to the normal running mode Reset to factory default To reset the factory default settings Open the inlet grid press the panel button ...

Page 10: ... cabinet A moderate amount of arcing or snapping may occur when the unit is turned on This may indicate that the cell s are still damp Turn the unit off and allow it more drying time or go to Program Setting 8 9 3 Media filter replacement The disposable media filter can only be used once and cannot be cleaned Replace as necessary 9 4 Activated carbon or Odor Free filter replacement The disposable ...

Page 11: ... causes a short circuit STANDBY led blinks Clean the electronic filter Crackling sound from the electronic filter Electronic filter dirty or wet Clean or dry the electronic filter Missing prefilter Install prefilter The air cleaner cannot be controlled manually Control is locked out See Program Setting 4 page 7 to unlock STANDBY led blinks Dirt in the electronic filter causes a short circuit Clean...

Page 12: ...25 0632 Media filter 2 pcs x x x x x 42 00 27b F825 0633 Media filter 40 pcs x x x x x 800 00 28 F825 0634 Electronic cell x x x x x 84 40 29a F825 0635 Activated carbon filter 72 pcs x x x x x x x x x 205 20 29b F825 0636 Activated carbon filter 625 pcs x x x x x x x x x 1 625 00 30a F825 0628 Activated carbon filter Odor Free option 2 pcs x x x x x x x x x 47 40 30b F825 0629 Activated carbon fi...

Page 13: ...082120 101203 C Page 12 Owner s manual Parts List 34 24 1 5 3 4 15 11 10 20 19 17 21 23 26 27 PROGRAM AUTO OFF 16 13 14 25 18 12 22 28 29 24 32 30 32 1 3 1 3 2 33 Replacement ionizing wires electronic cell ...

Page 14: ...16 5 1 Commande par le bouton frontal 16 5 2 Commande par la télécommande 16 5 3 Commande automatique mode AUTO 16 6 MODES DE PROGRAMMATION 16 6 1 Mode de Programmation 1 Indicateur Service 16 6 2 Mode de Programmation 2 Réinitialisation de l Indicateur Service 17 7 REPARATION DES PANNES 17 GUIDE DE SERVICE TECHNIQUE 18 8 AJUSTEMENT AUX CONDITIONS AMBIANTES SPÉCIFIQUES 18 9 REMPLACEMENT NETTOYAGE ...

Page 15: ...endommager l épurateur d air et entraîner des risques de chocs électriques d incendie ou de blessures corporelles Lors de la fixation des accessoires de montage évitez de forcer les vis pour les serrer vous risqueriez d endommager l épurateur d air ou d obtenir une installation peu sûre pouvant entraîner la chute de l épurateur d air Après son installation sur le mur ne changez pas l épurateur de ...

Page 16: ...essus de l épurateur d air N utilisez pas l appareil lorsque le fil électrique est endommagé Ne tirez pas sur le fil pour débrancher l appareil Protégez le fil contre la chaleur l huile et les objets abrasifs N enroulez pas un objet quelconque sur le fil N utilisez pas le fil pour tirer ou charrier l unité n utilisez pas le fil comme moyen de manutention ne le compressez pas pour le faire passer s...

Page 17: ...uiert l utilisation de deux exemplaires du même kit Pour le montage encastré du modèle simple utilisez le kit d installation F801 0196 Pour le modèle double utilisez le kit d installation F801 0197 Aucun composant pour montage au plafond ou encastrement dans le plafond n est compris dans les kits proposés Assurez vous de ce que les dispositifs de montage soient effectivement capables de supporter ...

Page 18: ... frontal la vitesse du ventilateur passe à STANDBY Pousez le bouton frontal le ventilateur s arrête OFF En poussant le bouton frontal sans cesse la commande passe à la vitesse suivante chaque seconde 5 2 Commande par la télécommande Voir fig 3 sur page 25 Indication de la vitesse du ventilateur sur la télécommande LOW basse MEDIUM normale HIGH élevée TURBO extrême Attention Si le moteur est tourné...

Page 19: ... 7 REPARATION DES PANNES Si les diodes et clignotent C est l Indicateur Service Il vous prévient de ce qu il est temps de remplacer ou nettoyer le s filtre s Appuyant quelconque bouton les diodes de l Indicateur Service cessent de clignoter L Indicateur Service clignotera à nouveau lorsque l unité aura été activée Après le remplacement du des filtre s réinitialisez l Indicateur Service dans le mod...

Page 20: ... la diode du STANDBY clignote brièvement toutes les deux secondes Programmation de l appareil OFF aucune diode ne clignote Appuyez V diode LOW clignote vous avez fixé le niveau de pollution sur BASSE Appuyez V diode MEDIUM clignote vous avez fixé le niveau de pollution sur NORMALE Appuyez V diode HIGH clignote vous avez fixé le niveau de pollution sur ELEVEE Appuyez V diode TURBO clignote vous ave...

Page 21: ...ibilité à la pollution sera réglée sur élevée Appuyez V diode TURBO est commuté et la sensibilité à la pollution sera réglée sur extrême Si vous désirez retourner sur l une des sensibilités à la pollution précédentes appuyez W Appuyez sur PROGRAM confirmez le mode 7 et allez vers le mode 8 Mode de Programmation 8 Période sans haute tension après intervention du service uniquement épurateurs d air ...

Page 22: ...tion de la capacité de nettoyage du filtre électronique Utilisez un chiffon humide pour essuyer tous les fils d ionisation en prenant soin de ne pas les endommager C Enlevez le les filtres s électronique s de la solution et rincez abondamment avec de l eau propre chaude D Permettez au x filtre s électronique s de s égoutter et de sécher pendant 2 heures au minimum Il est possible de tapoter légère...

Page 23: ...ltre électronique Le filtre électronique crépite Le filtre électronique est encrassé ou humide Nettoyer le filtre électronique ou bien le laisser correctement sécher Le pré filtre est manquant Montez le pré filtre L épurateur ne se laisse pas commander manuellement La commande a été bloquée Voir Mode de Programmation 4 page 20 pour le débloquer La diode STANDBY clignote Un court circuit s est prod...

Page 24: ...825 0631 Pré filtre 600 pièces x x x x x x x x x 27a F825 0632 Filtre média 2 pièces x x x x x 27b F825 0633 Filtre média 40 pièces x x x x x 28 F825 0634 Filtre électronique x x x x x 29a F825 0635 Filtre à charbon actif 72 pièces x x x x x x x x x 29b F825 0636 Filtre à charbon actif 625 pièces x x x x x x x x x 30a F825 0628 Filtre à charbon actif Odor Free option 2 pièces x x x x x x x x x 30b...

Page 25: ...03 C Page 24 Manuel opérateur Pièces Détachées 34 24 1 5 3 4 15 11 10 20 19 17 21 23 26 27 PROGRAM AUTO OFF 16 13 14 25 18 12 22 28 29 24 32 30 32 1 3 1 3 2 33 Remplacement des fils d ionisation du filtre électronique ...

Page 26: ... 7 1 2 3 4 A B C D E F G H I J K L M N O P Q click No mm inches A 554 21 81 B 497 19 57 C 463 18 23 D 298 11 73 E 215 8 46 F 92 3 62 6 G 629 24 76 No mm inches H 570 22 44 I 510 20 08 J 470 18 50 K 978 38 50 L 919 36 18 M 878 34 57 N 9 0 35 O 15 0 59 P 1054 41 50 7 Q 639 25 16 ...

Page 27: ...0 101203 C Controlling Indoor Comfort Worldwide Since 1937 St Louis Missouri Markham Ontario 314 577 1300 905 201 470 www white rodgers com The Emerson logo is a trademark and service mark of Emerson Electric Co ...