PARTS LIST
GC-1 / GC-2
844-874-7529
grind2energy.com
The Emerson logo is a trademark and a service mark of Emerson Electric Co.
InSinkErator may make improvements and/or changes in the specifications
at any time, in its sole discretion, without notice or obligation and further
reserves the right to change or discontinue models.
©2015 InSinkErator, a business unit of Emerson Electric Co. All Rights Reserved.
InSinkErator Division
Emerson Electric Co.
4700 21st Street
Racine, WI 53406-5093 USA
G2E015-15F-89-84
CODE DESCRIPTION
QTY
PART
NUMBER
1
Non-Metallic Enclosure
1
N/A
2
Door Disconnect Kit
1
14728
3
Pushbutton STOP (N.C. Red)
1
14158
4
Pushbutton START (N.O. Black)
1
14159
5
Pushbutton FLUSH (N.O. Yellow)
1
14470
6
Remote Sensor Light (FULL)
1
N/A
7
Pushbutton De-Jam (REV)
1
14370
8
24V Fuse
X
XXXXX
9
120V Fuse
X
XXXXX
10
Terminal Block - 3 Phase
18
14805
11
Transformer - 3 Phase
1
14185
12
Circuit Board, Printed
1
14788
13
Relay 3-Pole
1
14812
CODE DESCRIPTION
QTY
PART
NUMBER
14
Contactor - Aux Pump
1
14813
15
Mechanical Interlock
1
14169
16
Reversing Contactor - 3 Phase
1
14160
17
Relay 3-Pole
1
14813
18
Overload 208-230V
1
14792
18
Overload 380-460V
1
14793
19
Ground Lug
X
XXXXX
20
DC Supply For Pressure
X
XXXXX
21
Pressure Relay
X
XXXXX
22
Disposer Delay Time Relay
X
XXXXX
23
Timed off Relay
X
XXXXX
24
Forward Contactor
X
XXXXX
Solenoid Valve - 24 Volt Coil (Not Shown)
2
14494
MODEL ENGINEERING #
CERTIFIED
ELECTRICAL
GC-1
14176
UL & CUL
208-230 Volt / 10 HP / 3 Ph
GC-2
14176A
International
415 Volt / 5 HP / 3 Ph
Adjust
Power Supply
INPUT
N
N
DC ok
DC
ok
1 ON
0 OFF
2 2 2 4 4 4 7 10 11 12 15 M1 M2 M3 T1 T2 T3
L1
L2
L3
L1
L2
L3
GROUND
GROUND
GROUND
BLK BRN
BLU
BLU
TANK
FLUSH
START
STOP
WARNING
ELECTRICAL SHOCK HAZARD. DISCONNECT INCOMING POWER
BEFORE SERVICING CONTROL CENTER. FAILURE TO DO SO COULD
RESULT IN DEATH OR SERIOUS PERSONAL INJURY. DOOR
INTERLOCK SWITCHED DISCONNECT CONTROL CIRCUIT ONLY.
PRESS IF
JAMMED
Adjust
Power Supply
INPUT
N
N
DC ok
DC
ok
1 ON
0 OFF
2 2 2 4 4 4 7 10 11 12 15 M1 M2 M3 T1 T2 T3
L1
L2
L3
L1
L2
L3
GROUND
GROUND
GROUND
BLK BRN
BLU
BLU
TANK
FLUSH
START
STOP
WARNING
ELECTRICAL SHOCK HAZARD. DISCONNECT INCOMING POWER
BEFORE SERVICING CONTROL CENTER. FAILURE TO DO SO COULD
RESULT IN DEATH OR SERIOUS PERSONAL INJURY. DOOR
INTERLOCK SWITCHED DISCONNECT CONTROL CIRCUIT ONLY.
PRESS IF
JAMMED
Adjust
Power Supply
INPUT
N
N
DC ok
DC
ok
1 ON
0 OFF
2 2 2 4 4 4 7 10 11 12 15 M1 M2 M3 T1 T2 T3
L1
L2
L3
L1
L2
L3
GROUND
GROUND
GROUND
BLK BRN
BLU
BLU
TANK
FLUSH
START
STOP
WARNING
ELECTRICAL SHOCK HAZARD. DISCONNECT INCOMING POWER
BEFORE SERVICING CONTROL CENTER. FAILURE TO DO SO COULD
RESULT IN DEATH OR SERIOUS PERSONAL INJURY. DOOR
INTERLOCK SWITCHED DISCONNECT CONTROL CIRCUIT ONLY.
PRESS IF
JAMMED
2
3
8
11
15
13
7
18
2
1
5
6
4
17
12
16
14
9
19
21
20
10
22
23
24