Dosaodor-D
3
CHARACTERISTICS
Electronic Control Unit
Construction material
: 10/10 mm steel plate
Finish
: RAL 7032 grey epoxy powder coat
Door
: Lockable with window
Installation
: Wall mount
Weight
: 22 kg (49 lbs) (medium complexity configuration)
Power supply options
: 12Vdc+/-15% - 115 Vac 60Hz - 230 Vac 50Hz
Electromagnetic interference
: Consistent with 89/336/CE standard
Humidity
: 10% – 90% non-condensing
Input signals
Calibration cylinder high level
: Discrete (EExi)
Calibration cylinder low level
: Discrete (EExi)
Flow Computer alarm signal
: Discrete
Flow Computer instantaneous flow rate
: Pulse (max 1 Hz)
Flow Computer instantaneous flow rate
: Analog (4-20 mA)
Output signals
Injection solenoid valve control (Primary)
: Discrete (12 Vdc EExe)
Injection solenoid valve control (Secondary, B.2 only)
: Discrete (12 Vdc EExe)
Calibration cylinder refill valve
: Discrete (12 Vdc EExe)
Emergency circuit control
: Discrete (12 Vdc EExe)
Injected odorant
: Pulse (1 Hz)
Distributed gas volume
: Pulse (1 Hz)
Injector failure (Primary)
: Discrete
Injector failure (Secondary, B.2 only)
: Discrete
Emergency circuit enabled
: Discrete (Also indicates that the Dosaodor-D unit is in disabled mode)
Odorant tank level
: Discrete
Instantaneous odorant concentration
: Analog (4-20 mA)
Daily odorant concentration
: Analog (4-20 mA)
Communication ports
One RS-232 serial port is available for local configuration or
connected to an GSM/GPRS modem.
Display
Back-lit alphanumeric 4 line by 40 character LCD.
Operative modes
OFF – MANUAL – AUTOMATIC – WASHING all selectable by
appropriate function keys.
Operation INJECTOR 1 - INJECTOR 2 - INJECTOR 1-2
(with B.2 option only).
Configuration protection
Keyed switch for configuration mode selection and battery
backed memory to maintain internal configuration data in the
event of power failure.
Optional integrated printer
Dot matrix, 42 characters/line, allows for a local hard copy of
alarms, operating history and reports.