4.5  PROGRAMMING FROM PC TO INSTRUMENT 

The use of PROG TOOL along with Wizmate software allows to  verify and/or modify the 
parameters map of an instrument.  

The instrument to be programmed must be connected to the PROG TOOL following one of the 
schemes  indicated  in  the  following  pages  (connection  mode  depends  on  the  fact  that  the 
instrument has the RS485 serial port or not) and its compatibility (instrument model and software 
version) with Wizmate software must be verified using the table of Chapter 5 of this manual.  

NOTE:  parameters  reading  and/or  writing  is  possible  only  for  those  controllers  equipped  with 
RS485 or TTL serial communication port.  
For  all  instruments  not  equipped  with  serial  port  (PRIME  and  WING  BASIC  series)  it  is  only 
possible to create HOY KEYS with which is then possible to program devices.

 

 

CONNECTION  OF  AN  INSTRUMENT  EQUIPPED  WITH  RS485 
SERIAL PORT  

 

 

1. 

Connect the RS485 port of the instrument to the RS495 terminals of the PROG TOOL (16 
and 17) through a double wired cable, respecting the + and - polarity. 

2. 

Connect the “

+5V Supply

” connector placed on the PROG TOOL side to the TTL (Hot Key) 

port of the instrument by using the CAB/RS2 cable. This operation provides power supply to 
the instrument with no need for further connections. 

3. 

Connect the PROG TOOL to the PC by using the serial converter RS232/USB. 

4. 

It is now possible to check and eventually modify the programming of the instrument through 
the Wizmate software.  

 
 

 

 

Interface Led 

Instrument power supply 
(CAB/RS2) 

110Vac or 230Vac 

Power Supply 

2  wired  cable 
for Rs485 

Summary of Contents for dixell

Page 1: ...PROG TOOL ...

Page 2: ... the service staff with adequate technical training and experience in order to be aware of any possible danger Operations described in this manual are intended to be for exclusive use of the service staff The user is is not enabled to open the device CAUTION Dixell Srl reserves the right to modify this user s manual at any time without prior notice The latest version available can be dowloaded fro...

Page 3: ...a new purchase is made This equipment may contains hazardous substances Improper use or incorrect disposal can have adverse effects on human health and the environment The symbol shown on the product or the package indicates that the product be disposed of as separated waste Should the product be disposed of incorrectly sanctions may be applied as stipulated in applicable local regulations regardi...

Page 4: ...al the different functioning states Programmed HOT KEY to be copied Interface Led HOT KEY output port to program new hot keys Button to load parameters map in the new Hot Key Instruments without Rs485 TTL output for power supply and programming INSTRUMENTS with RS485 on board TTL connector for power supply and Rs485 port Green Led power supply On Yellow Led Hot Key programming Blinking yellow Led ...

Page 5: ...OOL front 3 Press the Copy button to start the key copying procedure During the operation the Copy Led is blinking green 4 After a few seconds the Copy Led stops blinking and provides the result of the operation RED Copy Led error during the HOT KEY programming repeat the operation and eventually replace the key GREEN Copy Led successfully performed operation Hot Key has been correctly programmed ...

Page 6: ...in the Hot Key Copy connector placed on the unit front 9 Press the Copy button placed on the PROG TOOL front the Copy Led starts blinking 10 After a few seconds the Copy Led stops blinking and provides the result of the operation RED Copy Led error during the HOT KEY programming repeat the operation and eventually replace the key GREEN Copy Led successfully performed operation Hot Key has been cor...

Page 7: ...port For all instruments not equipped with serial port PRIME and WING BASIC series it is only possible to create HOY KEYS with which is then possible to program devices CONNECTION OF AN INSTRUMENT EQUIPPED WITH RS485 SERIAL PORT 1 Connect the RS485 port of the instrument to the RS495 terminals of the PROG TOOL 16 and 17 through a double wired cable respecting the and polarity 2 Connect the 5V Supp...

Page 8: ...al converter RS232 USB 3 It is now possible to check and eventually modify the programming of the instrument through the Wizmate software 5 TECHNICAL DATA Power supply 115V 10 50 60 Hz 230V 10 50 60 Hz Power absorption 3VA max Operating temperature 0 60 C Relative humidity 20 85 non condensing Storage temperature 40 85 C 6 OPERATION For operational procedures refer to WIZMATE MANUAL in the Manuals...

Reviews: