1592010400 PROG TOOL EN 19.03.2020                                    PROG TOOL                      

 

    5/8

 

 

 

4.3  PROGRAMMING FROM HOT-KEY TO HOT-KEY 

This function allows to copy any HOT KEY that is already programmed. 

 

 

Connect the power supply to the  terminal blocks 13 and 14 

and make sure the “Power” 

Led is turned on. 

1. 

Insert the original key in the connector on the top side of the programmer. 

2. 

Insert the key to be programmed in the “Hot-Key Copy” connector placed on the PROG 
TOOL front 

3. 

Press the “Copy” button to start the key copying procedure. During the operation the “Copy” 
Led is blinking green 

4. 

After a few seconds the “Copy” Led stops blinking and provides the result of the operation 

RED  “Copy”  Led  = 

error  during  the  HOT  KEY  programming,  repeat  the  operation  and 

eventually replace the key. 

GREEN  “Copy”  Led  = 

successfully  performed  operation;  Hot  Key  has  been  correctly 

programmed. 

5. 

Remove the new key. It is possible to create further copies by inserting a new Hot Key to be 
programmed. 

 
 

 

Programmed Hot Key to be 
copied 

Interface Led 

Press to start copying 

Insert 

the 

key 

to 

be 

programmed 

Power Supply 

Summary of Contents for dixell

Page 1: ...PROG TOOL ...

Page 2: ... the service staff with adequate technical training and experience in order to be aware of any possible danger Operations described in this manual are intended to be for exclusive use of the service staff The user is is not enabled to open the device CAUTION Dixell Srl reserves the right to modify this user s manual at any time without prior notice The latest version available can be dowloaded fro...

Page 3: ...a new purchase is made This equipment may contains hazardous substances Improper use or incorrect disposal can have adverse effects on human health and the environment The symbol shown on the product or the package indicates that the product be disposed of as separated waste Should the product be disposed of incorrectly sanctions may be applied as stipulated in applicable local regulations regardi...

Page 4: ...al the different functioning states Programmed HOT KEY to be copied Interface Led HOT KEY output port to program new hot keys Button to load parameters map in the new Hot Key Instruments without Rs485 TTL output for power supply and programming INSTRUMENTS with RS485 on board TTL connector for power supply and Rs485 port Green Led power supply On Yellow Led Hot Key programming Blinking yellow Led ...

Page 5: ...OOL front 3 Press the Copy button to start the key copying procedure During the operation the Copy Led is blinking green 4 After a few seconds the Copy Led stops blinking and provides the result of the operation RED Copy Led error during the HOT KEY programming repeat the operation and eventually replace the key GREEN Copy Led successfully performed operation Hot Key has been correctly programmed ...

Page 6: ...in the Hot Key Copy connector placed on the unit front 9 Press the Copy button placed on the PROG TOOL front the Copy Led starts blinking 10 After a few seconds the Copy Led stops blinking and provides the result of the operation RED Copy Led error during the HOT KEY programming repeat the operation and eventually replace the key GREEN Copy Led successfully performed operation Hot Key has been cor...

Page 7: ...port For all instruments not equipped with serial port PRIME and WING BASIC series it is only possible to create HOY KEYS with which is then possible to program devices CONNECTION OF AN INSTRUMENT EQUIPPED WITH RS485 SERIAL PORT 1 Connect the RS485 port of the instrument to the RS495 terminals of the PROG TOOL 16 and 17 through a double wired cable respecting the and polarity 2 Connect the 5V Supp...

Page 8: ...al converter RS232 USB 3 It is now possible to check and eventually modify the programming of the instrument through the Wizmate software 5 TECHNICAL DATA Power supply 115V 10 50 60 Hz 230V 10 50 60 Hz Power absorption 3VA max Operating temperature 0 60 C Relative humidity 20 85 non condensing Storage temperature 40 85 C 6 OPERATION For operational procedures refer to WIZMATE MANUAL in the Manuals...

Reviews: