background image

 

1592010820 XWEB5000 PRO STP GB r1.0 18.03.2022.docx                                                     XWEB5000 PRO                                                                   

   3/20 

 

CAUTION:  TO  PREVENT  FLAMES  FROM  DEVELOPING  OR  ELECTRIC  SHOCK, 
AVOID ANY CONTACT BETWEEN THIS DEVICE AND RAIN OR WATER 

 

CAUTION: TO REDUCE THE RISK OF ELECTRIC 
SHOCK, DO NOT REMOVE THE COVER IT DOES NOT 
CONTAIN ANY PARTS THAT REQUIRE SERVICING BY 
THE USER ALWAYS HAVE QUALIFIED STAFF 
PERFORM THE PROCEDURES.

 

 

THE SYMBOL OF THE LIGHTNING BOLT INSIDE AN 
EQUILATERAL TRIANGLE IS USED TO ALERT THE 
USER OF THE POTENTIALLY DANGEROUS NON-
INSULATED ELECTRICAL VOLTAGES

 

 

THE SYMBOL OF THE EXCLAMATION MARK INSIDE 
AN EQUILATERAL TRIANGLE IS USED TO WARN THE 
USER THAT HE/SHE MUST PAY CLOSE ATTENTION 
TO THE TOPIC COVERED IN THIS MANUAL

 

 

CAUTION 

 

This  device  must  be  installed  exclusively  by  service  staff  with  suitable  technical 
training  and  experience,  who  are  aware  of  the  dangers  that  they  are  exposed  to. 
The  operations  described  herein  are  set  forth  exclusively  for  the  service  staff.  The 
user is not enabled to open the device. 

 

 

CAUTION 

 

Use only modems and usb-dongles officially supported by this monitoring unit. Dixell 
srl.  cannot  be  held  responsible  for  any  type  of  damage  resulting  from  the  use  of 
unsupported devices. 

 

 

CAUTION 

 

Dixell  srl  reserves  the  right  to  amend  this  manual  without  prior  notice.  The  latest 
available version can be downloaded from the internet site. 

 

 

CAUTION 

 

Immediately  after  the  power  failure,  no  new  data  is  recorded;  all  recorded  data  is 
kept  in  non-volatile  memory.  The  memory  is  electronic  and  no  data  is  kept  or 
conveyed to other media such as paper. When the memory is exhausted, the oldest 
data  is  lost  to  store  the  most  recent  data.  The  product  provides  memory 
consumption  indications  on  the  user  interface.  The  device  does  not  have  its  own 
power  supply.  The  recording  interval  can  be  configured  from  a  minimum  of  30 
seconds  to  a  maximum  of  1  day.  The  duration  of  the  recordings  depends  on  the 
interval  and  the  number  of  points  configured  for  each  device  in  configuration.  One 
year  of  data  logging  is  guaranteed  for  2  analog  resources  with  an  interval  of  15 
minutes,  per  configured  device.  Selecting  other  resources  can  affect  storage 
performance. 

 

 

CAUTION 

 

This  is  a  class  A  product.  It  can  cause  radio-interference  in  residential 
environments. Should this occur, the user should take suitable countermeasures 

 

 

CAUTION 

 

Dixell  srl  reserves  the  right  to  vary  the  composition  of  its  products  without  prior 
notice to the customer, ensuring the identical and unchanged features of the same. 

Summary of Contents for DIXELL XWEB1000D PRO

Page 1: ...XWEB5000 PRO V 1 0 ...

Page 2: ... 300 400 SERIES 11 5 2 2 CONFIGURATION FOR XJA XJP XJM MODELS 11 6 LOCAL CONNECTIVITY 12 7 REMOTE CONNECTIVITY 12 7 1 GENERAL AND MINIMUM REQUIREMENTS 12 7 2 DESKTOP SOFTWARE REQUIREMENTS PC 13 7 3 SOFTWARE MOBILE REQUIREMENTS SMARTPHONE TABLET 13 7 4 CONNECTIVITY WITH CROSS CABLE 14 7 5 INTRANET CONNECTIVITY OR LAN CONNECTION AND VPN 16 7 6 INTERNET CONNECTIVITY ON PUBLIC IP 17 7 7 WIFI CONNECTIV...

Page 3: ...age resulting from the use of unsupported devices CAUTION Dixell srl reserves the right to amend this manual without prior notice The latest available version can be downloaded from the internet site CAUTION Immediately after the power failure no new data is recorded all recorded data is kept in non volatile memory The memory is electronic and no data is kept or conveyed to other media such as pap...

Page 4: ...of 4 July 2012 on Waste Electrical and Electronic Equipment WEEE and to the relevant national implementation regulations we inform you that users of EEE in households there is an obligation not to dispose of WEEE as mixed urban waste and to separate waste collection of WEEE Public or private collection systems required by local laws must be used for disposal It is also possible at the end of its l...

Page 5: ...he brackets Removable female connectors 2x2ways 2x3ways 1x6ways 4 feet for TABLE mounting 6 Jumpers 1 DVI VGA Converter 1 Installation manual 2 ferrites If one of the following parts is damaged promptly contact your dealer You may also receive a modem or a wifi dongle which will not be included in the same package as a package option When working with a modem connection always check that the type ...

Page 6: ... of the RTC is 35 ppm the maximum drift of the clock in a year is therefore about 18 minutes Approvals The system consisting of this control and monitoring unit and Dixell temperature meters compliant with the EN13485 standard complies with the EC regulation no 37 2005 and in particular with the EN12830 standard Temperature recorders for the transport and storage and distribution of chilled frozen...

Page 7: ...holes on the underside of the device For rack installation on the other hand use the supplied brackets and screws 3 Connect it to the power mains by the supplied power cord Set the power plug up so that it is easily accessible at all times Note Do not turn the system on 4 Connect the RS485 the relays and digital inputs and end and or polarise the line if necessary 5 Connect any telephone lines and...

Page 8: ... without having a screen mouse and keyboard attached For example it is possible to use this initial system installation configuration and then disconnect them definitively if you only intend to set up access from the remote station If you intend to use external peripheral devices always connect them to the unit before turning it on Caution always and only connect the external peripheral devices be...

Page 9: ...ay attention in Keep the TTL cable away from any source of electromagnetic disturbance Connect each XJ485 module to the instrument with the TTL cable supplied with the module itself Mark the polarity of output 485 which must be respected when connecting the instruments to the network Below is a list of operating tips to obtain the best result in terms of instrument network reliability RS485 serial...

Page 10: ...disturbance Mount the supplied ferrites on the serial ports as shown in the figure Do not connect the shield of the serial cable to the earth of the electrical system Do not connect the Gnd terminal Draw a map of the installation you are performing it will be useful both in case of problems and in case of future changes the serial line must reach all the stations where the instruments must be cont...

Page 11: ...he jumper if the XWEB is in the middle of the RS485 line Notes on the use of polarization resistors POL POL In order to avoid false signals on the bus polarization resistors must be inserted It is important to note that they must be inserted in one and only one place in the network otherwise the communication will deteriorate the node in which they are inserted is irrelevant even if it could be co...

Page 12: ...olution higher than 1024x768 pixels Check your display s instruction manual for supported resolutions 7 REMOTE CONNECTIVITY 7 1 GENERAL AND MINIMUM REQUIREMENTS The user or the installer of XWEB can access its user interface as well as locally with screen keyboard and mouse also through a PC that must be connected and configured to be able to communicate with the XWEB network The XWEB Ethernet por...

Page 13: ...illa Firefox SUPPORTED 54 All newer computers are capable of meeting these requirements However it is advisable to use the advice of a computer expert to evaluate the computers to be purchased and or already in your possession In the following sections general information on possible network configurations will be provided Right from the start we recommend that you make use of IT experts and or yo...

Page 14: ...http 192 168 0 200 XWEB default address The connection procedure is complete when the login page opens up Enter user name and password to start using your XWEB Caution a pre requisite to setting the connection up correctly is that the XWEB address and network interface address on your PC need to have a compatible IP class For example with an XWEB network interface configured with 192 168 0 200 the...

Page 15: ...1592010820 XWEB5000 PRO STP GB r1 0 18 03 2022 docx XWEB5000 PRO 15 20 ...

Page 16: ...able to assign a valid IP address to the XWEB and be able to provide for your PC any software and credentials if you want to use a VPN network for access Before connecting the XWEB to the network check that the IP address you wish to use for the XWEB is actually free and therefore usable You could perform a PING to that address and if at least one reply is received at the PING the address must be ...

Page 17: ...ternet you need a public and static IP address which must be specifically requested from your ISP Internet Service Provider Tell your ISP that you want to install a webserver this will help them recognize your needs and provide you with an adequate connection It is highly recommended to obtain all the details of the supply contract for the management of any future connection problems Connection to...

Page 18: ...ess point XWEB is normally supplied preconfigured in this mode so that the user can search with his PC smartphone tablet to an XWEB PRO SSID network The default password is dixellxwebpro Fixed IP 172 21 0 1 Connection of XWEB to existing Wi Fi network XWEB can be connected via Wi Fi to a Wifi AccessPoint already present on the site In this case you need to temporarily access the XWEB interface wit...

Page 19: ...2 168 0 14 E mail Address ___________________________ example myXWEB001 company com Modem ___________________________ Telephone number ___________________________ 10 TRADEMARKS Consider It Solved and Intelligent Store are trademarks and Emerson Climate Technologies and the Emerson Climate Technologies logo are service marks and trademarks of Emerson Electric Co Windows and Internet Explorer are re...

Page 20: ...__________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ _________________________________________...

Reviews: