3. Ceiling Fan Assembly

(Continued)

DOWNROD

SETSCREW

Figure 3

7/8"

RED LEAD

WIRE
CONNECTORS

KNURLED KNOB

1" THREADED
STUD

MOTOR

MOTOR 
COUPLING
COVER

WIRE CONNECTOR

YELLOW LEADS

BROWN LEAD

Figure 4

SETSCREW

DOWNROD

PIN

HANGER BALL

CEILING COVER

Figure 5

6.

Install the setscrew (supplied in loose parts bag) in
the motor coupling and tighten using the 5/32"
setscrew wrench (supplied) (Figure 3).

7.

Screw two 1” threaded studs (provided) into the
motor (Figure 4). Leave approximately 7/8” of the
stud extending above the motor. Slide the motor
cover over the downrod and rotate the cover until the
threaded studs protrude; install two knurled knobs
(supplied) to secure the cover.

NOTE: Make sure the red and brown leads are
capped with wire connectors. Make sure the red,
brown, and yellow wires and wire connectors are
completely inside motor coupling cover and not
pinched between the motor coupling cover and
motor.

8.

Position the ceiling cover over the downrod. Be sure
the cover is oriented correctly, with the large opening
at the top (Figure 5).

9.

Reinstall the hanger ball on the downrod as
follows. Route the motor leads through the hanger
ball and slide the hanger ball over the downrod
(Figure 5). Install the pin through the holes at the top
of the downrod and slide the hanger ball up the
downrod, aligning the ball so the pin is
captured in the groove in the top of the hanger ball.
Pull the hanger ball up tight against the pin and
securely tighten the setscrew in the hanger ball.
A loose setscrew could create fan wobble.

10.

The blue, black and white leads exiting the downrod
are 80-inches long. Before installing fan, measure up
approximately 6 to 9-inches above the ball/downrod
assembly. Cut off excess leads and strip back
insulation 1/2-inch from end of leads.

It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened. Failure
to verify that the pin and setscrew are properly
installed could result in the fan falling.

WARNING

!

Summary of Contents for CROWN SELECT CF4501AP00

Page 1: ...ssing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Net Weight 23 8 Lbs Model Numbers CROWN SELECT Model Numbers Fan Blades Not Included CF4801AB00 CF4801AP00 CF4801BS00 CF4801GBZ00 CF4801GES00 CF4801ORB00 CF4801SW00 CF4801VNB00 CF4801WW00 CF4501AP00 CF4501GBZ00 CF4501GES00 CF4501VNB00 ...

Page 2: ...e your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING To avoid fire shock or injury do not use an Emerson or any other brand of control not specifically approved for this fan WARNING This product is designed to use only t...

Page 3: ...ur local retailer or catalog outlet for replacement before proceeding 2 Remove and discard the two cardboard shipping retainers securing the motor hub in the motor housing assembly 3 Remove the fan motor assembly from the protective plastic bag Place all carton contents on a protective surface A B D C F E G H PACKAGE CONTENTS 5 15 1 2 3 4 11 10 9 8 7 6 12 13 14 16 HARDWARE CONTENTS Part Descriptio...

Page 4: ...nts Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may n...

Page 5: ... through the holes in the motor coupling and the holes in the downrod Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the hanger ball to make sure the clevis pin is properly installed DOWN...

Page 6: ...e motor coupling cover and motor 8 Position the ceiling cover over the downrod Be sure the cover is oriented correctly with the large opening at the top Figure 5 9 Reinstall the hanger ball on the downrod as follows Route the motor leads through the hanger ball and slide the hanger ball over the downrod Figure 5 Install the pin through the holes at the top of the downrod and slide the hanger ball ...

Page 7: ...nd install the five blade assemblies ordered separately in accordance with Step 13 13 Attach one blade assembly to the motor hub using two 10 32 x 18mm oval head screws supplied Figure 7 Do not tighten completely at this time Install remaining blade assemblies in the same way Gently snug all flange screws to the motor hub working around the hub in a clockwise sequence Next securely tighten all fla...

Page 8: ... ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 9 WARNING 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 10 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was ju...

Page 9: ...d hot wire using wire connector supplied After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black blue and yellow leads on the other side of the outlet box 5 How to Wire Your Ceiling Fan Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is...

Page 10: ...g assembly Figure 14 2 Slide the large pendant onto the the speed control pull chain secure by connecting the coupling to the chain Slide the pendant onto the accent light pull chain secure by connecting the coupling to the chain Figure 15 3 Assembly of the ceiling fan is now complete Restore electrical power to the branch circuit at the fuse box or breaker panel 4 When controlled by a wall switch...

Page 11: ...STRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish 10 Accessories This product is designed to use only those parts supplied with this product and or any accesso...

Page 12: ...12 U L Model No CF4801 and CF4501 11 Repair Parts 6 13 1 2 3 16 14 15 7 10 20 19 24 18 17 5 4 23 27 12 11 29 30 25 26 31 18 28 32 11 12 33 22 8 21 9 ...

Page 13: ... VNB 23 Motor 762508 762508 762508 762508 Parts Bag containing 764196 1 764196 1 764196 1 764196 1 4 Pin Clevis 1 5 Clip Hairpin 1 11 Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 18mm 11 20 Screw 8 32 x 3 8 2 21 Screw 10 24 x 14mm 21 22 Washer Flat 21 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxiliary Capa...

Page 14: ...764196 1 764196 1 4 Pin Clevis 1 5 Clip Hairpin 1 11 Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 18mm 11 20 Screw 8 32 x 3 8 2 21 Screw 10 24 x 14mm 21 22 Washer Flat 21 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxiliary Capacitor 762242 762242 762242 762242 762242 25 Cover Switch Cup 760671 760671 19 760...

Page 15: ... Coupling 2 12 Pendant 2 14 Wire Connector 3 15 Wrench Setscrew 1 16 Stud Threaded 1 1 4 2 17 Lockwasher 2 18 Knob Knurled 4 19 Screw 10 32 x 18mm 11 20 Screw 8 32 x 3 8 2 21 Screw 10 24 x 14mm 21 22 Washer Flat 21 27 Setscrew 1 31 Stud Threaded 1 2 24 Auxiliary Capacitor 762242 762242 762242 762242 25 Cover Switch Cup 760671 25 760671 SW 760671 VNB 760671 2 26 Harness 761450 2 761450 8 761450 2 7...

Page 16: ...housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned OFF 5 Screws holding blades to flanges are 5 Tighten screws securely loose 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Raise motor cover and tighten setscrew securely excessively 2 Setscrew in hanger ball downrod 2 Tighten the setscrew in the hanger ball a...

Page 17: ...17 emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No CF4801 and CF4501 Notes ...

Page 18: ...18 U L Model No CF4801 and CF4501 Notes ...

Page 19: ...er this limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when re...

Page 20: ...e 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74470001 Form No BP7447 1 Revision 131113 U L Model No CF4801 and CF4501 Printed in China 11 13 ...

Reviews: