10. The blue, black and white leads exiting the downrod
are 80-inches long. Before installing fan, measure
up approximately 6 to 9-inches above the
ball/downrod assembly. Cut off excess leads and
strip back insulation 1/2-inch from end of leads.
NOTE: If you are installing your fan with a SR330
Remote Control or SW350 Wall Control, Do Not
Cut Terminal Off of the Yellow Lead.
(See Section A.)
6. Install the setscrew (supplied in loose parts bag) in
the motor coupling and tighten using the 5/32"
setscrew wrench (supplied) (Figure 3B).
7. Screw two 1” threaded studs (provided) into the
motor (Figure 4B). Leave approximately 7/8” of the
stud extending above the motor. Slide the motor
cover over the downrod and rotate the cover until
the threaded studs protrude; install two knurled
knobs (supplied) to secure the cover.
NOTE: Make sure the red and brown leads are capped
with wire connectors. Make sure the red, brown, and
yellow wires and wire connectors are completely
inside motor coupling cover and not pinched between
the motor coupling cover and motor.
8. Position the ceiling cover over the downrod. Be
sure the cover is oriented correctly, with the large
opening at the top (Figure 5B).
9. Reinstall the hanger ball on the downrod as
follows. Route the motor leads through the hanger
ball and slide the hanger ball over the downrod
(Figure 5B). Install the pin through the holes at the
top of the downrod and slide the hanger ball up
the downrod, aligning the ball so the pin is
captured in the groove in the top of the hanger
ball. Pull the hanger ball up tight against the pin
and securely tighten the setscrew in the hanger
ball. A loose setscrew could create fan wobble.
DOWNROD
SETSCREW
Figure 3B
9
It is critical that the clevis pin in the motor coupling
is properly installed and the setscrew securely
tightened. Failure to verify that the pin and setscrew
are properly installed could result in the fan falling.
WARNING
!
It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are
properly installed could result in the fan falling.
WARNING
!
7/8"
RED LEAD
WIRE
CONNECTORS
KNURLED KNOB
1" THREADED
STUD
MOTOR
MOTOR
COUPLING
COVER
WIRE CONNECTOR
YELLOW LEADS
BROWN LEAD
Figure 4B
SETSCREW
DOWNROD
PIN
HANGER BALL
CEILING COVER
Figure 5B
11. Use three 10-32 x 3/8" pan head screws and flat
washers (supplied) to secure flange to blade
(Figure 6B). Repeat for the remaining four blades.
12. Use the 10 round recessed holes in the motor hub
marked with "5" and install the five blade assemblies
(ordered separately) in accordance with Step 13.
13. Attach one blade assembly to the motor hub using
two 10-32 x 5/8" oval head screws (supplied)
(Figure 7B). Do not tighten completely at this time.
Install remaining blade assemblies in the same
way. Gently snug all flange screws to the motor
hub, working around the hub in a clockwise
sequence. Next, securely tighten all flange screws,
again working in a clockwise sequence. Failure to
follow this procedure could result in fan wobble.
This completes the blade installation.
BLADE
BLADE
FLANGE
10-32 x 3/8"
PAN HEAD
SCREW (3)
FLAT WASHER (3)
Figure 6B