![Emerson CROWN CF4500AB04 Owner'S Manual Download Page 12](http://html.mh-extra.com/html/emerson/crown-cf4500ab04/crown-cf4500ab04_owners-manual_102838012.webp)
Trouble Shooting
TROUBLE
PROBABLE CAUSE
SUGGESTED REMEDY
1. Fan will not start.
1. Fuse or circuit breaker blown.
1. Check main and branch circuit fuses or
circuit breakers.
WARNING:
Make sure main power is
turned off.
2. Loose power line connections to the fan,
2. Check line wire connections to fan and
or loose switch wire connections in the
switch wire connections in the switch
switch housing.
housing.
2. Fan sounds noisy.
1. Blades not attached to fan.
1. Attach blades to fan before operating.
2. Loose screws in motor housing.
2. Check to make sure all screws in motor
housing are snug (not over-tight).
3. Screws securing fan blade flanges to
3. Check to make sure the screws which
motor hub are loose.
attach the fan flanges to the motor hub
are tight.
WARNING:
Make sure main power is
turned off.
4. Wire connectors inside switch housing
4. Check to make sure wire connectors in
rattling.
switch housing are not rattling against
each other or against the interior wall of
the switch housing.
5. Screws holding blades to flanges are loose.
5. Tighten screws securely.
3. Fan wobbles
1. Setscrew in motor coupling is loose.
1. Raise motor cover and tighten setscrew
excessively.
securely.
2. Setscrew in hanger ball/downrod assembly
2. Tighten the setscrew in the hanger ball/
is loose.
downrod assembly.
3. Screws securing fan blade flanges to motor
3. Check to be sure screws which attach
hub are loose.
the fan blade flanges to the motor hub
are tight.
4. Fan blade flanges not seated properly.
4. Check to be sure the fan blade flanges
seat firmly and uniformly to the surface
of the motor hub. If flanges are seated
incorrectly, loosen the flange screws and
retighten according to Step 15, 13, or 17
in Sections “A” or “B” Assembly
Instructions”.
5. Hanger bracket and/or ceiling outlet box
5. Tighten the hanger bracket screws to the
is not securely fastened.
outlet box, and/or secure outlet box.
6. Fan blades out of balance.
6. Interchanging an adjacent (side-by-side)
blade pair can redistribute the weight
and result in smoother operation. Or use
supplied balancing kit to balance blades.
WARNING:
FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER
BEFORE TROUBLE SHOOTING YOUR FAN.
12
This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Company. Substitution of parts or
accessories not designated for use with this product
by Emerson Company could result in personal injury
or property damage.
WARNING
!
Accessories
The use of any other control not specifically
approved for this fan could result in fire, shock and
personal injury.
1. Ceiling Fan Light Kits (see store or catalog).
2. Ceiling Fan/Light Controls (see store or catalog).
3. Downrod Extension Kits (see store or catalog).
WARNING
!
!
!
!