TWO SCREWS
SUPPLIED WITH
OUTLET BOX
HANGER
BRACKET
TAB
OUTLET
BOX
OUTLET
BOX
HANGER
BRACKET
HANGER BALL/
DOWNROD ASSEMBLY
NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.
Figure 11A
Figure 12A
17. Carefully lift the fan and seat the hanger
ball/downrod assembly on the hanger bracket
that was just attached to the outlet box (Figure
12A). Be sure the groove in the ball is lined up
with tab on the hanger bracket (Figure 11A).
18. Position the receiver, SW375, by passing the
opening in the receiver over the downrod (Figure
13A).
19. Connect the black wire from the wiring harness to
the black (hot) supply wire (Figure 4A). Connect
the white wire from the wiring harness to the white
(neutral) supply wiring. Connect the green ground
wires from the hanger bracket and the hanger ball
to the supply ground wire. Use wire connectors
supplied with your ceiling fan.
16. Securely attach the hanger bracket to the outlet
box using the two screws supplied with the outlet
box (Figure 11A).
7
CEILING
FLOOR
AT LEAST
7'
Figure 10A
The fan must be hung with at least 7' of clearance
from floor to blades (Figure 10A).
WARNING
!
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked acceptable for
fan support, and use screws supplied with outlet
box. Most outlet boxes commonly used for support
of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified
electrician if in doubt.
The outlet box must be securely anchored and capable
of withstanding a load of at least 50 lbs.
WARNING
!
WARNING
!
Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.
WARNING
!
Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.
WARNING
!
To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is
grounded, contact a licensed electrician for advice,
as it must be grounded for safe operation.
To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.
WARNING
!
WARNING
!
10-32 x 5/8" OVAL HEAD SCREWS
(2 PER BLADE ASSEMBLY)
Figure 9A
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
WARNING
!
20. Securely connect the wiring harness connector to
the receiver connector, and connect the blue and
yellow wires to the blue and yellow wires from the
receiver (Figure 4A).