AGL_Unit_ZX_Small_E_Rev03
5
2.5 Nomenclature
The model designation contains the following technical information about the refrigeration unit:
Figure 2: Nomenclature ZX Small units
2.6 Application range
2.6.1
Qualified refrigerants and oils
Qualified
refrigerants
R450A, R513A
& R134a
R404A, R407A, R407F,
R448A & R449A
R448A & R449A
ZXME-013E*301
ZXME-015E*301
ZXME-018E*301
ZXME-013E*302
ZXME-015E*302
ZXME-018E*302
ZXLE-018E*302
ZXLE-023E*302
ZXLE-028E*302
Qualified
servicing oils
Emkarate RL 32 3MAF
Mobil EAL Arctic 22CC
Oil charge
(litres)
0.74
Table 3: Qualified refrigerants and oils
2.6.2
Application limits
For application envelopes, please refer to the compressor application envelopes which can be
found in Copeland Select software, available at
Copeland ZX Small refrigeration units can be used at ambient temperatures from -15 to +43 °C.
For lower ambient temperatures please contact your local Application Engineering representative.
2.7 Bill of material
Unit
BOM
Family
Introduction
date
Controller
Suction
accumulator
Compressor
BOM
Medium- or
low-pressure
refrigerant
301
ZXME
03/2019
No
No
524
Low
302
ZXME
03/2019
No
No
524
Medium
302
ZXLE
01/2021
No
No
618
Medium
Table 4: BOM