EMERSON QUICK START GUIDE

The Quick Start Guide covers the installation
instructions common for ceiling fan operations. If
additional assistance with wiring, alternate hanging
systems, or lighting options, proceed to the complete
instructions of this Owner’s Manual.

The Quick Start Guide sections include page numbers
to correspond with the appropriate sections of the
Owner’s Manual for detailed instructions.

*

See Unpacking Instructions for a complete list of
parts for installation. 

Installation of Downrod (page 76)

1.

Remove the hanger ball from
the downrod.

2.

Install the downrod to the
motor coupling using the
clevis pin and hairpin clip.

3.

Tighten the setscrews.

1.

Disconnect electrical power to
the branch circuit at the
circuit breaker or fuse box
before attempting to install
the ceiling fan hanger bracket
on the outlet box.

CEILING

FLOOR

AT LEAST

7'

2.

The fan must be hung with at
least 7’ of clearance from
floor to blades.

3.

Attach the hanger bracket to
the outlet box.

4.

Seat the hanger ball/downrod
assembly on the hanger
bracket.

Hanging Your Ceiling Fan (page 10)

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable for Fan
Support”, and use screws supplied with outlet box. Most
outlet boxes commonly used for support of light fixtures
are not acceptable for fan support and may need to be
replaced. Consult a qualified electrician if in doubt.

!

WARNING

Installation of Blade Assembly (page 8) 

1.

Turn fan assembly upside
down in preparation for
mounting fan blade
assemblies.

2.

To ensure proper blade
assembly, make sure the label
on the blades are facing the
bottom of the ceiling fan.
Slide blade through center
slot in fan housing. Mount
blade to fan housing using
three 3/16-24 x 1/2” slotted
Phillips washer head blade
screws.

Installation of Switch Housing (page 8)

1.

Remove two of the four
screws in the motor assembly
and loosen the remaining two
screws.

2.

Connect the terminals of the
lower housing assembly to
the terminals of the fan motor
assembly.

Installation of Ceiling Fan (page 8)

1.

Remove the three screws pre-
installed on top of the fan
assembly. Install the coupler
cover and ceiling cover onto
the downrod. Reinstall the
three screws through the
coupler cover. 

2.

Reinstall the hanger ball onto
the downrod, place the pin
into the hanger ball and
tighten the setscrew.

Turning off wall switch is not sufficient. To avoid possible electrical
shock, be sure electricity is turned off at the main fuse or circuit
breaker box before wiring. All wiring must be in accordance with
National and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical shock.

!

WARNING

ETL Model No.: CF955-3

Summary of Contents for CF955BS 03

Page 1: ...mbers shown on the product with your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we...

Page 2: ...ecommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician NOTE This fan is suitable for use with solid state speed controls WARNING To reduce the risk of fire or electrical shock this fan should only be used with fan speed control Model No FR 7861LMA manufactured by Rhine Electric Co ...

Page 3: ...t boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Installation of Blade Assembly page 8 1 Turn fan assembly upside down in preparation for mounting fan blade assemblies 2 To ensure proper blade assembly make sure the label on the blades are facing the bottom of the ceiling fan Slide...

Page 4: ...fail change the remote code and repeat Steps 1 and 2 as necessary until the fan successfully completes the programming procedure NOTE Fan installation must be completed including the installation of the fan blades before testing the remote control 4 Your SR600 Fan Light remote control has full control of your fan speed air flow direction and light intensity NOTE The following procedure must be com...

Page 5: ...remote control transmitter i One coupler cover j Four 13 watt GU 24 fluorescent lamps k One loose parts bag containing 1 Sixteen 3 16 24 x 1 2 slotted Phillips washer head blade screws 2 Three wire connectors 3 Two 1 1 4 threaded studs 4 Two lockwashers 5 Two knurled knobs 6 One clevis pin 7 One hairpin clip 8 One 1 25A 125V fuse spare 9 One 5 32 32 x 375 pan head screw spare 10 One 5 32 32 x 75 s...

Page 6: ...our Emerson ceiling fan comes supplied with a Fan Light Remote Control which consists of a receiver mounted inside the ceiling cover of the fan motor housing This system allows you to regulate your ceiling fan speed and light ON OFF 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves ...

Page 7: ...properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed 3 While pulling up on the downrod securely tighten the setscrew in the motor coupling Figure 3 NOTE The setscrew must be properly installed as described above or fan wobble could result 4 Remove the three screws pre installed on top of the fan assembly and retain fo...

Page 8: ...LL Figure 4 MOTOR HUB 3 16 24 x 1 2 SLOTTED PHILLIPS WASHER HEAD BLADE SCREWS FAN BLADE BLADE SLOT IN HOUSING LABEL LOCATED ON BOTTOM OF BLADE Figure 5 TERMINALS LOWER HOUSING ASSEMBLY FAN MOTOR ASSEMBLY REMOVE 2 SCREWS LOOSEN 2 SCREWS FUSE AND FUSE HOLDER Figure 6 8 The fan comes with black and white leads that are 80 long Before installing fan measure up approximately 6 to 9 inches above top of ...

Page 9: ...ore wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician WARNING Pour réduire le risque d incendie de choc...

Page 10: ... montées solidement et être capables de supporter au moins 50 lbs 22 5 kg Utilisez seulement un boîtier de prises de courant homologué U L comportant les termes Acceptable pour le raccordement d un ventilateur AVERTISSEMENT CEILING FLOOR AT LEAST 7 Figure 8 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX Figure 9 Hanger bracket must seat firmly against outlet box If the outlet bo...

Page 11: ...s grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING Pour ne pas risquer de choc électrique assurez vous que l électricité est coupée au niveau du disjoncteur boîtier de fusibles avant de réaliser le raccordement REMARQUE si vous ne savez pas vraiment si le boîtier de prises de courant est mis à la terre contactez un électricien professionnel pour ...

Page 12: ... turn until studs protrude through the holes in the ceiling cover Figure 12 Effectuez une inspection pour vous assurer que toutes les connexions sont bien serrées y compris la connexion de mise à la terre et qu aucun fil nu n est visible près des connecteurs à l exception du fil de mise à la terre Ne mettez pas le ventilateur en marche avant que les pales ne soient à leur place Ceci causerait un f...

Page 13: ...ur fan and light go on and off without using your control you may be getting interference from other remote units such as garage door openers car alarms or security systems To remedy this situations simply change the combination code in your transmitter and receiver 1 Remove the battery cover by pressing firmly below the arrow and sliding the cover off the control Figure 14 2 Install two AAA alkal...

Page 14: ...g the receiver Program the receiver to the new frequency by repeating the Setting Operating Frequency of Remote Control and High Speed Conditioning instructions IMPORTANT The following steps must be completed immediately following the frequency programming of the ceiling fan 1 Press the speed button until all 6 LED indicators are lit Let the fan operate on high speed for 2 minutes without interrup...

Page 15: ...cessory Ceiling Fan Controls SR600 Handheld Transmitter SW605 Wall Transmitter SR650 Wall Handheld Transmitter WARNING N utilisez pas d eau lorsque vous nettoyez votre ventilateur de plafond Cela risquerait d endommager le moteur ou les lames et de créer le risque de choc électrique AVERTISSEMENT L utilisation de toute autre commande non approuvée spécifiquement pour ce ventilateur risquerait de c...

Page 16: ...ger bracket and or ceiling outlet box is not 5 Tighten the hanger bracket screws to the outlet box securely fastened and or secure outlet box 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Raise coupler cover and tighten the setscrew securely excessively 2 Setscrew in hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod loose assembly 3 Screws securing fan flywh...

Page 17: ...se the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This equipment has been certified to comply with the limits for a class B computing device pursuant to FCC Rules In order to maintain compliance with FCC regulations shielded c...

Page 18: ...Repair Parts 18 ETL Model No CF955 3 9 14 8 20 15 13 19 21 4 6 7 17 18 1 2 3 5 12 16 10 11 ...

Page 19: ...rts Bag Containing 762029 2 762029 1 762029 2 4 Wire Connector 3 5 Stud Threaded 1 1 4 2 6 Lockwashers 2 7 Knob Knurled 2 8 Pin Clevis 9 Clip Hairpin 10 Screw Slotted Phillips Washer Head 3 16 24 x 1 2 16 11 Screw Pan Head 5 32 32 x 375 spare 12 Screw Slotted Head 5 32 32 x 75 spare 13 Fuse 1 25A 125V spare 14 Lower Housing Assembly 763746 763746 2 763746 1 15 Glass Shade 762031 762031 762031 16 B...

Page 20: ...thorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass ...

Reviews: