background image

12

How to Wire Your Ceiling Fan 

(continued)

Installing Lamps and Glass Globe

6.

Secure the ceiling cover in place by sliding
lockwashers over the threaded studs and installing
the two knurled knobs (supplied). (Figure 12.)
Tighten the knurled knobs securely until the ceiling
cover fits snugly against the ceiling and the hole in
the ceiling cover is clear of the downrod.

To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.

WARNING

!

Pour ne pas risquer d'incendie ou de choc électrique,
assurez-vous que les fils électriques sont
complètement à l'intérieur du boîtier de prises de
courant et qu'ils ne sont pas pincés entre le revêtement
de plafond et le plafond.

AVERTISSEMENT 

!

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

WARNING

!

4.

Screw the two threaded studs (supplied) into the
tapped holes in the hanger bracket.

5.

Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the
ceiling cover (Figure 12).

Effectuez une inspection pour vous assurer que toutes
les connexions sont bien serrées, y compris la
connexion de mise à la terre, et qu'aucun fil nu n'est
visible près des connecteurs, à l'exception du fil de
mise à la terre. Ne mettez pas le ventilateur en marche
avant que les pales ne soient à leur place. Ceci
causerait un fonctionnement très bruyant et risquerait
d'endommager le ventilateur. 

AVERTISSEMENT 

!

LOCKWASHERS (2)

CEILING COVER

THREADED STUD

KNURLED KNOB

Figure 12

FLAT AREA
OF GLASS BOWL

RAISED DIMPLES OF
LIGHT KIT HOUSING

FLOURESCENT 
LAMP PLUG (4)

Figure 13

1.

Carefully position one of the GU24 fluorescent
bulbs (supplied) into the light fitter socket, aligning
the two pins on the bottom of the bulb into the
socket holes. Twist the bulb clockwise,
approximately 1/16 turn, to engage the bulb pins
into the light socket holes.

2.

Install the remaining three GU24 fluorescent bulbs
in the same manner.

3.

Place the glass bowl into the opening in the lower
housing assembly, aligning the three flat areas on
the top edge of the glass with the three raised
dimples on the lower housing assembly and turn
the glass bowl clockwise until it stops (Figure 13).

NOTE: periodically check that the glass bowl is
seated fully clockwise in the lower housing
assembly.

ETL Model No.: CF955-3

Summary of Contents for CF955BS 03

Page 1: ...mbers shown on the product with your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we...

Page 2: ...ecommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician NOTE This fan is suitable for use with solid state speed controls WARNING To reduce the risk of fire or electrical shock this fan should only be used with fan speed control Model No FR 7861LMA manufactured by Rhine Electric Co ...

Page 3: ...t boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Installation of Blade Assembly page 8 1 Turn fan assembly upside down in preparation for mounting fan blade assemblies 2 To ensure proper blade assembly make sure the label on the blades are facing the bottom of the ceiling fan Slide...

Page 4: ...fail change the remote code and repeat Steps 1 and 2 as necessary until the fan successfully completes the programming procedure NOTE Fan installation must be completed including the installation of the fan blades before testing the remote control 4 Your SR600 Fan Light remote control has full control of your fan speed air flow direction and light intensity NOTE The following procedure must be com...

Page 5: ...remote control transmitter i One coupler cover j Four 13 watt GU 24 fluorescent lamps k One loose parts bag containing 1 Sixteen 3 16 24 x 1 2 slotted Phillips washer head blade screws 2 Three wire connectors 3 Two 1 1 4 threaded studs 4 Two lockwashers 5 Two knurled knobs 6 One clevis pin 7 One hairpin clip 8 One 1 25A 125V fuse spare 9 One 5 32 32 x 375 pan head screw spare 10 One 5 32 32 x 75 s...

Page 6: ...our Emerson ceiling fan comes supplied with a Fan Light Remote Control which consists of a receiver mounted inside the ceiling cover of the fan motor housing This system allows you to regulate your ceiling fan speed and light ON OFF 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves ...

Page 7: ...properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed 3 While pulling up on the downrod securely tighten the setscrew in the motor coupling Figure 3 NOTE The setscrew must be properly installed as described above or fan wobble could result 4 Remove the three screws pre installed on top of the fan assembly and retain fo...

Page 8: ...LL Figure 4 MOTOR HUB 3 16 24 x 1 2 SLOTTED PHILLIPS WASHER HEAD BLADE SCREWS FAN BLADE BLADE SLOT IN HOUSING LABEL LOCATED ON BOTTOM OF BLADE Figure 5 TERMINALS LOWER HOUSING ASSEMBLY FAN MOTOR ASSEMBLY REMOVE 2 SCREWS LOOSEN 2 SCREWS FUSE AND FUSE HOLDER Figure 6 8 The fan comes with black and white leads that are 80 long Before installing fan measure up approximately 6 to 9 inches above top of ...

Page 9: ...ore wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician WARNING Pour réduire le risque d incendie de choc...

Page 10: ... montées solidement et être capables de supporter au moins 50 lbs 22 5 kg Utilisez seulement un boîtier de prises de courant homologué U L comportant les termes Acceptable pour le raccordement d un ventilateur AVERTISSEMENT CEILING FLOOR AT LEAST 7 Figure 8 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX Figure 9 Hanger bracket must seat firmly against outlet box If the outlet bo...

Page 11: ...s grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING Pour ne pas risquer de choc électrique assurez vous que l électricité est coupée au niveau du disjoncteur boîtier de fusibles avant de réaliser le raccordement REMARQUE si vous ne savez pas vraiment si le boîtier de prises de courant est mis à la terre contactez un électricien professionnel pour ...

Page 12: ... turn until studs protrude through the holes in the ceiling cover Figure 12 Effectuez une inspection pour vous assurer que toutes les connexions sont bien serrées y compris la connexion de mise à la terre et qu aucun fil nu n est visible près des connecteurs à l exception du fil de mise à la terre Ne mettez pas le ventilateur en marche avant que les pales ne soient à leur place Ceci causerait un f...

Page 13: ...ur fan and light go on and off without using your control you may be getting interference from other remote units such as garage door openers car alarms or security systems To remedy this situations simply change the combination code in your transmitter and receiver 1 Remove the battery cover by pressing firmly below the arrow and sliding the cover off the control Figure 14 2 Install two AAA alkal...

Page 14: ...g the receiver Program the receiver to the new frequency by repeating the Setting Operating Frequency of Remote Control and High Speed Conditioning instructions IMPORTANT The following steps must be completed immediately following the frequency programming of the ceiling fan 1 Press the speed button until all 6 LED indicators are lit Let the fan operate on high speed for 2 minutes without interrup...

Page 15: ...cessory Ceiling Fan Controls SR600 Handheld Transmitter SW605 Wall Transmitter SR650 Wall Handheld Transmitter WARNING N utilisez pas d eau lorsque vous nettoyez votre ventilateur de plafond Cela risquerait d endommager le moteur ou les lames et de créer le risque de choc électrique AVERTISSEMENT L utilisation de toute autre commande non approuvée spécifiquement pour ce ventilateur risquerait de c...

Page 16: ...ger bracket and or ceiling outlet box is not 5 Tighten the hanger bracket screws to the outlet box securely fastened and or secure outlet box 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Raise coupler cover and tighten the setscrew securely excessively 2 Setscrew in hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod loose assembly 3 Screws securing fan flywh...

Page 17: ...se the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This equipment has been certified to comply with the limits for a class B computing device pursuant to FCC Rules In order to maintain compliance with FCC regulations shielded c...

Page 18: ...Repair Parts 18 ETL Model No CF955 3 9 14 8 20 15 13 19 21 4 6 7 17 18 1 2 3 5 12 16 10 11 ...

Page 19: ...rts Bag Containing 762029 2 762029 1 762029 2 4 Wire Connector 3 5 Stud Threaded 1 1 4 2 6 Lockwashers 2 7 Knob Knurled 2 8 Pin Clevis 9 Clip Hairpin 10 Screw Slotted Phillips Washer Head 3 16 24 x 1 2 16 11 Screw Pan Head 5 32 32 x 375 spare 12 Screw Slotted Head 5 32 32 x 75 spare 13 Fuse 1 25A 125V spare 14 Lower Housing Assembly 763746 763746 2 763746 1 15 Glass Shade 762031 762031 762031 16 B...

Page 20: ...thorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass ...

Reviews: