background image

U.L. Model No.: CF936

Part No. F40BP73820000

Printed in China  12/08

Form No. BP7382

Air Comfort Products

DIVISION OF EMERSON ELECTRIC CO.

8100 W. Florissant ¥ St. Louis, MO 63136

Summary of Contents for CF936GBZ00

Page 1: ...thorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass ...

Page 2: ...oxes listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan mus...

Page 3: ...completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retail er or catalog outlet for replacement before pro ceeding 2 Remove the fan assembly from the p...

Page 4: ... ceiling cover and the coupling cover are both oriented correctly Figure 3 6 Reinstall the hanger ball Figure 4 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely t...

Page 5: ... closes properly 13 Remove the three switch housing mounting screws Figure 7 from the switch housing plate Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate Secure the switch housing assembly by installing the three mounting screws Figure 8 NOTE Do not pinch wires between the switch housing assembly and t...

Page 6: ...tric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician in in doubt WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs Use...

Page 7: ...this product by Emerson Electric Co could result in personal injury or property damage WARNING NOTE CEILING COVER OMITTED FOR CLARITY GROUND WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK AND BLUE FAN WIRES Figure 12 Check to see that all connections are tight including ground and that...

Page 8: ... required and should be avoided to prevent damage to finish Maintenance Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceil ing fan Here are a few tips to ensure qual...

Page 9: ...setscrew securely excessively securely 2 Setscrew in the hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod assembly loose 3 Screws securing fan blade flanges to motor are loose 3 Check to be sure screws which attach the fan blade flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly ...

Page 10: ...10 4 9 8 5 7 11 12 17 16 1 2 3 10 6 13 19 15 14 13 19 18 Repair Parts U L Model No CF936 ...

Page 11: ... 6 Ceiling Canopy 762456 GBZ 762456 8 9 Coupling Cover 762463 GBZ 762463 12 12 Wiring Harness 763758 763758 14 Switch Housing 763087 GBZ 763087 PW 16 Flange set of 5 763088 GBZ 763088 PW 17 Blade set of 5 761859 32 761859 30 Owner s Manual BP7382 BP7382 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE F...

Page 12: ...U L Model No CF936 Part No F40BP73820000 Printed in China 12 08 Form No BP7382 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 ...

Page 13: ...15 ...