background image

Mobile Box Fan

 

User’s Manual

Sauk Rapids, MN 56379 USA 

• 

Toll Free 

(800) 779-3267

Fax: 320-251-2922 

• 

www.schaeferventilation.com 

• 

[email protected]

© 2018 Pinnacle Climate Technologies, Inc.

SCFB-419

MOB4851-2

WARNING! CALIFORNIA PROPOSITION 65:

 This product can expose you to chemicals, 

including lead, which are known to the State of California to cause cancer and birth defects or other 
reproductive harm. For more information go to www.P65Warnings.ca.gov.

Summary of Contents for MOB4851-2

Page 1: ...nfo pinnacleclimate com 2018 Pinnacle Climate Technologies Inc SCFB 419 MOB4851 2 WARNING CALIFORNIA PROPOSITION 65 This product can expose you to chemicals including lead which are known to the State of California to cause cancer and birth defects or other reproductive harm For more information go to www P65Warnings ca gov ...

Page 2: ...ormation All information illustrations and specifications in this manual are based on the latest product information available at the time of printing We reserve the right to make changes at any time without notice SAFETY RECOMMENDATIONS This is an electric device with moving components There is the possibility of fire electric shock or injury to persons Ensure all the safety recommendations are a...

Page 3: ...ll times back of fan with guards removed AIR FLOW Unpack your Mobile Box Fan The unit is shipped fully assembled and strapped to a pallet Inspect the unit and note any suspected damage when accepting delivery Remove the straps and lift the unit from the pallet Caution This unit is very heavy When removing this unit from the pallet manually several people should assist to avoid injury Inspect your ...

Page 4: ...k bearings Use a grease gun and lithium based Shell 2 grease Insert 4 grams into each grease zerk every 7000 hours of run time Do not overgrease Grease zerks TROUBLESHOOTING Symptom Possible causes Corrective action Fan not operating 1 Ensure you have power 1 Plug fan in 2 Ensure wiring is done properly 2 Ensure wiring is correct 3 Blown fuse or tripped breaker 3 Replace fuse or reset breaker 4 Fa...

Page 5: ...PBBA205 16 Pillow Block Bearing 2 FS1X15 5 Fan Shaft 1 x151 2 3 AX 47 V Belt Cogged 4 MSMP P Motor Shaft Mounting Pan 5 48UPRIGHT Motor Mount Upright for 48 6 48VENTURI 48 Orifice 7 AK 104C Fan Shaft Pulley 1 Bore 7 AK 26 Motor Pulley 5 8 Bore 8 GFB 485P 48 Galvanized Fan Blade 5 wing 9 CS596 Motor 1 HP 115V 2 speed 10 48FGO P 48 Guard 11 BFWB Box Fan Wheel Bracket 12 WC CASTERLGLK Large Locking C...

Page 6: ...tive product or component returned upon approval to PCT F O B Sauk Rapids Minnesota This warranty does not cover failure damage or malfunction as a result of Improper installation or installation not in accordance with installation instructions Operating conditions that vary from PCT s operating instructions Misuse abuse negligence alteration or accident Transporting the product Improper operation...

Reviews: