background image

1. Check to see that you have received the following

parts:

NOTE: If you are uncertain of part description,
refer to exploded view illustration.

a. Fan motor assembly
b. One switch housing assembly
c. Five fan blades
d. One ceiling cover
e. Five blade flanges
f. One hanger ball/downrod assembly
g. One hanger bracket
h. One coupling cover
i. One loose parts bag containing:

1. Sixteen M5 x 6 washer head

blade screws

2. One M6 x 14 flange screw with

lockwasher

3. Two wood pendants
4. Two couplings
5. Three wire connectors
6. Two threaded studs
7. Two lockwashers
8. Two knurled knobs
9. One clevis pin

10. One hairpin clip

This Manual Is Designed to Make it as Easy as Possible for You to

Assemble, Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver

One stepladder

One 1/4” blade screwdriver

One wire stripper

Three wire connectors (supplied).

MATERIALS

Wiring outlet box and box connectors must be of type
required by the local code. The minimum wire would
be a 3-conductor (2-wire with ground) of following
size: 

3

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each step is completed, place a
check mark in the box. This will insure that all steps have been completed and will be helpful in finding
your place should you be interrupted.

NOTE: Place the parts from the loose parts bags
in a small container to keep them from being lost.
If any parts are missing, contact your local retail-
er or catalog outlet for replacement before pro-
ceeding.

2. Remove the fan assembly from the protective plas-

tic bag. Place the fan assembly into the upper
foam pad with the top of the motor facing up.

The upper foam pad serves as a holder for the fan
during the first stages of assembly.

COUPLING
COVER

LOOSE
PARTS
BAG

HANGER BALL/
DOWNROD
ASSEMBLY

HANGER
BRACKET

FAN
BLADES

FAN MOTOR
ASSEMBLY

CEILING
COVER

BLADE
FLANGES

SWITCH CUP
ASSEMBLY

Before assembly your ceiling fan, refer to section on
proper method of wiring your fan (page 7). If you feel
you do not have enough wiring knowledge or experi-
ence, have your fan installed by a licensed electrician.

WARNING

!

Do not install or use fan if any part is damaged or
missing. Call Toll-Free:

1-800-654-3545

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or acces-
sories not designated for use with this product by
Emerson Electric Co. could result in personal injury
or property damage.

WARNING

!

WARNING

!

U.L. Model No.: CF936

Summary of Contents for CF936GBZ00

Page 1: ...thorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass ...

Page 2: ...oxes listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan mus...

Page 3: ...completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retail er or catalog outlet for replacement before pro ceeding 2 Remove the fan assembly from the p...

Page 4: ... ceiling cover and the coupling cover are both oriented correctly Figure 3 6 Reinstall the hanger ball Figure 4 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely t...

Page 5: ... closes properly 13 Remove the three switch housing mounting screws Figure 7 from the switch housing plate Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate Secure the switch housing assembly by installing the three mounting screws Figure 8 NOTE Do not pinch wires between the switch housing assembly and t...

Page 6: ...tric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician in in doubt WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs Use...

Page 7: ...this product by Emerson Electric Co could result in personal injury or property damage WARNING NOTE CEILING COVER OMITTED FOR CLARITY GROUND WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK AND BLUE FAN WIRES Figure 12 Check to see that all connections are tight including ground and that...

Page 8: ... required and should be avoided to prevent damage to finish Maintenance Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceil ing fan Here are a few tips to ensure qual...

Page 9: ...setscrew securely excessively securely 2 Setscrew in the hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod assembly loose 3 Screws securing fan blade flanges to motor are loose 3 Check to be sure screws which attach the fan blade flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly ...

Page 10: ...10 4 9 8 5 7 11 12 17 16 1 2 3 10 6 13 19 15 14 13 19 18 Repair Parts U L Model No CF936 ...

Page 11: ... 6 Ceiling Canopy 762456 GBZ 762456 8 9 Coupling Cover 762463 GBZ 762463 12 12 Wiring Harness 763758 763758 14 Switch Housing 763087 GBZ 763087 PW 16 Flange set of 5 763088 GBZ 763088 PW 17 Blade set of 5 761859 32 761859 30 Owner s Manual BP7382 BP7382 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE F...

Page 12: ...U L Model No CF936 Part No F40BP73820000 Printed in China 12 08 Form No BP7382 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 ...

Page 13: ...15 ...

Reviews: