22
ETL Model No.: CF880L
8. Wall Control Installation
(Continued)
3-WAY WIRING DIAGRAM:
NEW CONSTRUCTION
NOTE: Retrofit 3-way installations are likely to
include two Traveler Wires between the two Wall
Boxes. In new construction, only one Traveler Wire
Is required (See Figure 31).
8.14
Screw the Wall Control into Wall Box using the supplied
Screws. Leave the Wall Control in “OFF” mode until
Fan installation is completed.
8.15
The Wall Control is supplied with a White, Ivory, and
Almond color Switch Covers. Choose the finish that
best suits your needs and snap the Cover onto the Wall
Control (Figure 31).
8.16
Next, install the other Wall Control (sold separately) into
the Wall Box containing the Load Wire. Connect the
Black Wire of the Wall Control to the Traveler Wire(s)
already connected to the Black Wire (in the other wall
box). Secure with Wire Connectors supplied.
Figure 31
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.
WARNING
!
STANDARD WIRING FOR EXISTING
3-WAY CONTROLS
EXISTING
WALL CONTROL
HOT
BLK
TRAVELER
WIRES
B
L
A
C
K
LOAD
FAN/LIGHT
WALL
CONTROL
BLK
B
L
A
C
K
LOAD
TRAVELER
WIRES
BLK
BLK
FAN/LIGHT
WALL
CONTROL
HOT
BLK
SECOND
WALL CONTROL
PURCHASED
SEPARATELY
OFF
ON
....
OFF
ON
....
3-WAY WIRING DIAGRAM: RETROFIT
8.17
Connect one Black Wire of the Wall Control to the
“load” (black) Wire and secure with Wire Connector
supplied.
8.18
Connect one Black Wire of the Wall Control to both
remaining Traveler Wires in the Wall Box and secure
with Wire Connector supplied.