If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.

1.

Connect the green grounding lead from the hanger
ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this
may be a bare wire or wire with green colored
insulation). Securely connect wires with wire
connectors supplied. (Figure 13.)

NOTE: If you are using an Emerson Light Fixture
with your fan, see Light Fixture Owner’s Manual for
wiring.

9

emersonfans.com

Please contact 1-800-654-3545 for further assistance

E.T.L. Model No.: CF772

How to Wire Your Ceiling Fan

To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.

NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.

WARNING

!

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or
accessories not designated for use with this product
by Emerson Electric Co. could result in personal injury
or property damage.

WARNING

!

2.

Securely connect the fan motor white wire to the
supply white (neutral) wire using wire connector
supplied (Figure 13). Securely connect the fan motor
black wire and blue wire to the supply black (hot)
wire using wire connector supplied (Figure 13). After
connections have been made, turn leads upward
and carefully push leads into the outlet box, with the
white and green leads on one side of the outlet box
and the black and blue leads on the other side of the
outlet box.

3.

Screw the two threaded studs (supplied) into the
tapped holes in the hanger bracket.

4.

Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the
ceiling cover (Figure 14).

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

WARNING

!

NOTE: CEILING COVER
OMITTED FOR CLARITY.

GROUND
WIRE

LISTED
WIRE
CONNECTOR (3)

GREEN WIRE
(GROUND) FROM
HANGER BRACKET

GREEN WIRE
(GROUND) FROM
HANGER BALL

WHITE SUPPLY
(NEUTRAL)

WHITE FAN
WIRE

BLACK SUPPLY
(HOT)

BLACK AND BLUE
FAN WIRES

Figure 13

CEILING 
COVER

THREADED STUD (2)

KNURLED KNOB (2)

LOCKWASHERS (2)

Figure 14

5.

Secure the ceiling cover in place by sliding
lockwashers over the threaded studs and installing
the two knurled knobs (supplied). (Figure 14.)
Tighten the knurled knobs securely until the ceiling
cover fits snugly against the ceiling and the hole in
the ceiling cover is clear of the downrod. Your fan is
now wired to be turned on and off from the fan
switch.

6.

Connect the wood ball with chain to the 3-speed
switch pull chain.

To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box and
not pinched between the ceiling cover and the ceiling.

WARNING

!

Summary of Contents for CF755BS00

Page 1: ...EREY II 52 Ceiling Fan Owner s Manual Model Numbers CF755BS00 Brushed Steel CF755ORB00 Oil Rubbed Bronze CF755SW00 Satin White Net Weight 25 4 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m EST Monday Friday 1 800 654 3545 www emersonfans com ...

Page 2: ...n blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock...

Page 3: ...t If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly A B C D E I G F H PACKAGE CONTENTS 1 4 3 5 11 7 8 9 6 2 10 Part De...

Page 4: ...nger ball for reinstallation in Step 5 2 Separate untwist and unkink the three 80 motor leads Route the motor lead wires through the downrod Align the clevis pin holes in the downrod with the holes in the motor coupler Install the clevis pin and secure with the hairpin clip Figure 2 The clevis pin must go through the holes in the motor coupler and the holes in the downrod Be sure to push the strai...

Page 5: ... blue black and white leads that are 80 inches long Before installing the fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 7 Mount blade flange to fan blade using three 10 32 x 25 slotted Phillips washers head screws Figure 5 8 Repeat this procedure for the remaining four blades and flange...

Page 6: ... be mated correctly color to color before they can be engaged Make sure the connector latch closes properly 16 Position the switch housing assembly on the switch housing cover plate and align the holes in the switch housing assembly with the holes in the plate Secure the switch housing assembly by installing the three switch housing screws supplied Figure 9 NOTE Do not pinch wires between the swit...

Page 7: ...savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install the fan 8 9 feet above the floor for optimal airflow...

Page 8: ...ersonal injury mount fan to outlet box marked Acceptable for Fan Support of 15 9kg 35 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 10 WARN...

Page 9: ... wire using wire connector supplied Figure 13 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box 3 Screw the two threaded studs supplied into the tapped holes in the hanger bracket 4 Lift the ceiling cover up to the threaded stud...

Page 10: ...en cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING REVERSING SWITCH SPEED CONTROL SWITCH PULL CHAIN IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive...

Page 11: ...le 4 Some fan motors are sensitive to signals from Solid State speed control variable speed controls If Solid State Control is used and motor noise results choose an alternative control method 5 Screws holding blades to flanges are loose 5 Tighten screws securely 3 Fan wobbles 1 Setscrews in motor coupler are not 1 Raise coupler cover and tighten setscrews securely excessively tightened securely 2...

Page 12: ...12 E T L Model No CF772 Repair Parts 1 5 2 3 6 17 7 18 9 8 12 13 22 23 21 19 10 15 4 16 20 11 14 ...

Page 13: ...ng of 1 Hanger Bracket 2 Hanger Ball 3 Downrod 4 5 Parts Bag Containing 764388 CHRM 764388 BLOX 764388 CHRM 4 Wire Connector 3 5 Threaded Stud 2 6 Lockwasher 2 7 Knurled Knob 2 8 Pin Clevis 9 Clip Hairpin 10 Wood Ball Chain 11 Screw 1 4 20 x 5 11 12 Screw 10 32 x 25 16 13 Screw Switch Cup 4 14 Screw Switch Adapter 1 15 Screw Center Plug 1 16 Blade Balance Kit 17 Ceiling Canopy 764389 BS 764389 ORB...

Page 14: ...14 E T L Model No CF772 Notes ...

Page 15: ...is limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returni...

Page 16: ...r Service 8 a m 6 p m EST Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74670000 Form No BP7467 Revision 130227 E T L Model No CF772 Printed in China 02 13 ...

Reviews: