6

OUTLET
BOX

HANGER
BRACKET

HANGER BALL/
DOWNROD ASSEMBLY

Figure 3

NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.

Figure 8

2. Carefully lift the fan and seat the hanger ball/

downrod assembly on the hanger bracket that was
just attached to the outlet box (Figure 8). Be sure
the groove in the ball is lined up with tab on the
hanger bracket (Figure 7).

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

WARNING

!

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

WARNING

!

1. Securely attach the hanger bracket to the outlet

box using the two screws supplied with the outlet
box. (Figure 7.)

How to Hang Your

Ceiling Fan

AT LEAST

7'

CEILING

FLOOR

Figure 6

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET
BOX

Figure 2

Figure 7

The fan must be hung with at least 7' of clearance
from floor to blades (Figure 6).

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

WARNING

!

WARNING

!

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable
for Fan Support”, and use screws supplied with
outlet box. Most outlet boxes commonly used for
support of light fixtures are not acceptable for fan
support and may need to be replaced. Consult a
qualified electrician if in doubt.

WARNING

!

The outlet box and joist must be securely mounted
and capable of supporting at least 50 lbs. Use only a
U.L. outlet box listed as “Acceptable for Fan
Support”.

WARNING

!

U.L. Model No.: CF705

Summary of Contents for CF705AB04

Page 1: ...r You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does...

Page 2: ...port and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at...

Page 3: ...lace a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retail er or catalog outlet for replacement before proceeding 2 Remove the fan assembly from the protective pl...

Page 4: ...through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the hanger ball to make sure the clevis pin is properly inst...

Page 5: ...ling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes ...

Page 6: ... LEAST 7 CEILING FLOOR Figure 6 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX Figure 2 Figure 7 The fan must be hung with at least 7 of clearance from floor to blades Figure 6 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or...

Page 7: ...ward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box GROUND WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK AND BLUE FAN WIRES Figure 9 NOTE CEILING COVER OMITTED F...

Page 8: ...nstallation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install the fan 8 9 feet above the floor for optimal air flow Consult your Emerson Retailer for ...

Page 9: ...o be sure screws which attach the fan blade flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling out...

Page 10: ...ll parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 U L Model No CF705 ...

Page 11: ... 5 761935 6 Owner s Manual BP7224 8 BP7224 8 BP7224 8 BP7224 8 BP7224 8 BP7224 8 BP7224 8 Repair Parts Listing Key Model No No Description CF705AW04 CF705WB04 CF705CK04 CF705BC04 CF705ORB04 CF705AGW04 CF705BZH04 Hanger Ball Assembly 760750 41 760750 39 760750 43 760750 44 760750 48 760750 50 760750 51 Consisting of 1 Hanger Bracket 2 Hanger Ball 3 Downrod Parts Bag Containing 762897 1 762897 76289...

Page 12: ...Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP72240008 Printed in China 04 08 Form No BP7224 8 U L Model No CF705 ...

Reviews: