1. Check to see that you have received the following

parts:

NOTE: If you are uncertain of part description,
refer to exploded view illustration.

a. Fan motor assembly
b. One switch housing assembly
c. Five fan blades
d. One ceiling cover
e. Five blade flanges
f. One hanger ball/downrod assembly
g. One hanger bracket
h. One loose parts bag containing:

1. Sixteen M5 x 6 washer head 

blade screws

2. One M6 x 14 flange screw

with lockwasher

3. One wood pendant
4. One coupling
5. Three wire connectors
6. Two threaded studs
7. Two lockwashers
8. Two knurled knobs
9. One clevis pin

10. One hairpin clip

This Manual Is Designed to Make it as Easy as Possible for You to

Assemble, Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver

One stepladder

One 5/16” blade screwdriver

One wire stripper

Three wire connectors (supplied).

MATERIALS

Wiring outlet box and box connectors must be of type
required by the local code. The minimum wire would
be a 3-conductor (2-wire with ground) of following
size:

3

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each step is completed,
place a check mark in the box. This will insure that all steps have been completed and will be helpful
in finding your place should you be interrupted.

NOTE: Place the parts from the loose parts bags
in a small container to keep them from being lost.
If any parts are missing, contact your local retail-
er or catalog outlet for replacement before
proceeding.

2. Remove the fan assembly from the protective plas-

tic bag. Place the fan assembly into the upper
foam pad with the top of the motor facing up.

The upper foam pad serves as a holder for the fan
during the first stages of assembly.

SWITCH CUP
ASSEMBLY

COUPLING
COVER

LOOSE PARTS
BAG

FAN MOTOR
ASSEMBLY

HANGER
BRACKET

FAN
BLADES

BLADE
FLANGES

CEILING
COVER

HANGER BALL/
DOWNROD
ASSEMBLY

Before assembly your ceiling fan, refer to section on
proper method of wiring your fan (page 7). If you feel
you do not have enough wiring knowledge or experi-
ence, have your fan installed by a licensed electrician.

WARNING

!

Do not install or use fan if any part is damaged or
missing. Call Toll-Free:

1-800-654-3545

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or acces-
sories not designated for use with this product by
Emerson Electric Co. could result in personal injury
or property damage.

WARNING

!

WARNING

!

U.L. Model No.: CF705

Summary of Contents for CF705AB04

Page 1: ...r You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does...

Page 2: ...port and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at...

Page 3: ...lace a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retail er or catalog outlet for replacement before proceeding 2 Remove the fan assembly from the protective pl...

Page 4: ...through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the hanger ball to make sure the clevis pin is properly inst...

Page 5: ...ling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes ...

Page 6: ... LEAST 7 CEILING FLOOR Figure 6 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX Figure 2 Figure 7 The fan must be hung with at least 7 of clearance from floor to blades Figure 6 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or...

Page 7: ...ward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box GROUND WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK AND BLUE FAN WIRES Figure 9 NOTE CEILING COVER OMITTED F...

Page 8: ...nstallation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install the fan 8 9 feet above the floor for optimal air flow Consult your Emerson Retailer for ...

Page 9: ...o be sure screws which attach the fan blade flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling out...

Page 10: ...ll parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 U L Model No CF705 ...

Page 11: ... 5 761935 6 Owner s Manual BP7224 8 BP7224 8 BP7224 8 BP7224 8 BP7224 8 BP7224 8 BP7224 8 Repair Parts Listing Key Model No No Description CF705AW04 CF705WB04 CF705CK04 CF705BC04 CF705ORB04 CF705AGW04 CF705BZH04 Hanger Ball Assembly 760750 41 760750 39 760750 43 760750 44 760750 48 760750 50 760750 51 Consisting of 1 Hanger Bracket 2 Hanger Ball 3 Downrod Parts Bag Containing 762897 1 762897 76289...

Page 12: ...Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP72240008 Printed in China 04 08 Form No BP7224 8 U L Model No CF705 ...