76
100-412-196 REV. 06
7.4
Alarms/Errors
When the system encounters an error condition, an error message is displayed on the LCD
of the LPX power supply, and the Alarm/Error icon will appear on the LCD.
NOTICE
Press the Reset key to reset alarms/errors.
Table 7.3
Alarms/Errors
Alarm/Error
Alarm/
Error Code
Description
Overload
E0:20
Will occur if the analog controller overload
signal is active (current/voltage/
temperature/frequency beyond normal
operating specifications).
Invalid entry
E2:06
Will occur if a parameter or register setting
is outside of its valid range.
Timeout
E2:08
Will occur if cycle timeout is reached. See
6.4 System Configuration Registers
more information.
Time ON + Time OFF >
Total Time
E2:09
Will occur if the current cycle preset has a
Time ON + Time OFF setting higher than
the Total Time value at the moment the
cycle begins.
Start still active after end
of cycle
E6:01
Will occur if Start signal or start button
press are detected at power-up or if the
signal is not removed within 2 seconds after
the last ultrasonic cycle finished.
Ground detect active in
ready
E6:05
If ground detect register is set to ON, error
will occur when the horn touches an anvil
which has been isolated from earth ground
before the cycle begins.
RAM failure
EA:01
During power-up and preset recalling
memory is verified. This alarm will result if
a RAM memory failure is detected.
Summary of Contents for Branson LPX
Page 4: ...iv 100 412 196 REV 06 ...
Page 6: ...vi 100 412 196 REV 06 ...
Page 8: ...viii 100 412 196 REV 06 ...
Page 10: ...x 100 412 196 REV 06 Table 7 2 System Trouble Analysis Chart 73 Table 7 3 Alarms Errors 76 ...
Page 24: ...14 100 412 196 REV 06 ...
Page 33: ...100 412 196 REV 06 23 Chapter 3 Delivery and Handling 3 1 Delivery and Handling 24 ...
Page 38: ...28 100 412 196 REV 06 4 1 4 Declaration of Conformity Figure 4 1 Declaration of Conformity ...
Page 76: ...66 100 412 196 REV 06 ...
Page 85: ...100 412 196 REV 06 75 Figure 7 2 LPX Power Supply Interconnect Diagram ...