100-214-251 REV. 05
83
model). Hold Time and the selectable Afterburst (AB) Delay parameters can be adjusted
from all three welding modes.
NOTICE
Note that, while AB Time and AB Delay are selectable, they do not have to be set. The
two parameters work in tandem - if AB Time is selected, then AB Delay must also be
selected, Afterburst is used to release workpieces that stick to the horn face after
welding.
Table 6.1 Parameter Functions
Parameters
Mode
Switch
Function
Weld Time
All
Mode
sets the amount of time ultrasonic energy is
applied to the workpiece. In Collapse or
Absolute Distance Modes the weld time
parameter acts as a cycle abort condition.
Ensure Time is setup to allow for the
collapse or absolute distances to be
attained during a weld.
Collapse
Distance IW+
only
Collapse
Mode
sets the amount of collapse distance
travelled from TRS while ultrasonics were
active. Note that the actual collapse
includes distance travelled during Hold
Time which, depending on your application,
may increase the weld collapse distance.
Absolute
Distance IW+
only
Absolute
Mode
sets the amount of absolute distance
travelled from ULS while ultrasonics were
active. Note that the actual absolute
includes distance travelled Hold Time
which, depending on your application, may
increase or decrease the weld absolute
distance.
Hold Time
All modes
HOLD TIME
sets the amount of time force is applied to
the workpiece after ultrasonic energy is
turned off, and while the horn is still
contacting the workpiece.
AB Time
All modes
AB TIME
if selected, controls the length of time
ultrasonic energy is active after AB Delay.
Aids in dislodging a workpiece from the
horn, if necessary. Used in conjunction with
AB Delay.
AB Delay
All modes
AB DELAY
if selected, controls the amount of time
between the removal of force from the
workpiece and the point at which AB Time
starts. Aids in dislodging a workpiece from
the horn, if necessary, Required with AB
Time.
100-214-251 IWoper.book Page 83 Friday, June 16, 2017 4:12 PM
Summary of Contents for Branson 2000 Series
Page 9: ...viii 100 214 251 REV 05 100 214 251 IWoper book Page viii Friday June 16 2017 4 12 PM ...
Page 47: ...38 100 214 251 REV 05 100 214 251 IWoper book Page 38 Friday June 16 2017 4 12 PM ...
Page 83: ...74 100 214 251 REV 05 100 214 251 IWoper book Page 74 Friday June 16 2017 4 12 PM ...
Page 89: ...80 100 214 251 REV 05 100 214 251 IWoper book Page 80 Friday June 16 2017 4 12 PM ...
Page 129: ...120 100 214 251 REV 05 100 214 251 IWoper book Page 120 Friday June 16 2017 4 12 PM ...
Page 135: ...126 100 214 251 REV 05 100 214 251 IWoper book Page 126 Friday June 16 2017 4 12 PM ...