100-214-251 REV. 05
107
6.6
Resetting the System
During powerup, you can restore the weld parameters to their Cold Start (factory-set)
values. Follow the step for your welder below.
• For the IW+ welders, Press both the FAST UP and FAST DOWN switches until the welder displays
“coldstart” and goes to Time mode
• For the IW welders, Press both the FAST UP and FAST DOWN switches until the welder displays
“RDY” and goes to Time mode
This will set Weld and Hold Time to 50 ms (the minimum value) and disable AB Delay, AB
Time and all limits. This procedure also functions if you have activated Display Lock.
100-214-251 IWoper.book Page 107 Friday, June 16, 2017 4:12 PM