5.
Install the actuator to the bracket. Tighten all bolts and apply the correct torque
(refer to Table 8).
Table 8.
Bottom flange torque values
Actuator Size
ISO Pattern
Torque (Nm)
Torque (lbf.ft)
Thread
Min.
Max.
Thread
Min.
Max.
12
F04
M6
4.5
5
10-24UNC
3.3
3.7
25
F03 inner pattern
M5
2.0
3.0
10-24UNC
1.5
2.2
F05 outer pattern
M6
4.5
5.0
1/4"-20
3.3
3.7
40, 65, 100
F05 inner pattern
M6
4.5
5.0
1/4"-20
3.3
3.7
F07 outer pattern
M8
10.5
12.5
5/16"-18
7.7
9.2
150, 200, 350
F07 inner pattern
M8
10.5
12.5
5/16"-18
7.7
9.2
F10 outer pattern
M10
21.0
24.5
3/8"-16
15.5
18.1
600
F10 inner pattern
M10
21.0
24.5
3/8"-16
15.5
18.1
F12 outer pattern
M12
34.5
43.0
1/2"-13
25.4
31.7
950
F10 inner pattern
M10
21.0
24.5
3/8"-16
15.5
18.1
F14 outer pattern
M16
90.0
104.0
5/8"-11
66.4
76.7
1600, 2500
F16 inner pattern
M20
170.0
204.0
3/4"-10
125.4
150.5
F25* outer pattern 4x M16
90.0
104.0
4x 5/8"-11
66.4
76.7
4000
F16 inner pattern
M20
170.0
204.0
3/4"-10
125.4
150.5
F25 outer pattern 8x M16
90.0
104.0
8x 5/8"-11
66.4
76.7
6.
When required, mount or adjust the visual indicator (22).
Figure 12
Indicator mounting
Indicator mounting “In-line”
Indicator mounting “Across Line”
Size 12 - 350
Size 600 - 4000
21
21
90°
90°
90°
21
21
Installation, Operation and Maintenance Manual
DOC.IOM.EF.EN Rev. 7
September 2017
17
Section 4: Installation