7
Installation, Operation and Maintenance Manual
VCIOM-15792-EN Rev. 0
October 2020
Section 2: Installation
Installation
2.4
Actuator Assembly on the Valve
2.4.1
Types of Assembly
The adapter pedestal in fabricated carbon steel is specifically designed for adaptation to
any type of valve with provision for local indicator, limit switches and other accessories
(on request).
Lift the actuator by safety-hook for chains using the lifting-points (see Section 2.2) on
the top of actuator for handling, transporting and assembling in vertical position
(see Figure 3). For handling, transporting and assembling the actuator in horizontal
position by safety-hook for chains use the lifting-points on the top of cylinder head-flange
and on coupling flange (see Figure 4).
2.4.2
Assembly Procedure
!
WARNING
Failure to comply with the following procedures may impair product warranty. Installation,
commissioning and maintenance and repair works should be carried out by qualified staff.
A non-conforming assembly could be the source of serious accidents.
For actuator assembly on the valve:
NOTICE
Check that the assembly position, as shown on the documentation, complies with system’s
geometry. Check the consistency of the parts of actuator-valve coupling.