Selection Diagram
Figure 6
Selection of the viscosity grade is made on the basis of starting viscosity with ambient
temperature (consider pour point where necessary) and optimum operating viscosity
according to system and operating data. In case of operation for a long time at
temperatures exceeding 70 °C, the oil will be broken down and thus loose its lubricating
properties. In order to guarantee a long service life for the installation, a good and reliable
filtration is necessary.