Requirements
Installation
ACC/ARTM-7221/FC Installation Guide (6806800E98A)
31
To guarantee proper RTM operation, you have to make sure that the temperature at the
following location is not exceeded.
Altitude
Up to +3,000 m
Up to +12,000 m
Vibration
5-20 Hz
20-250 Hz
0.5 mm amplitude 1g
1 mm amplitude 2.0 g
Shock
5 g/11 ms halfsine
according to Emerson-
internal environmental
requirements
15 g/11 ms half sine according to Emerson-internal
environmental requirements
Free Fall
1,200 mm/all edges and corners
Table 2-1 Environmental Requirements (continued)
Requirement
Operating
Non-Operating
Location
Component
Temperature Limit
1
Installed hard disk
60ºC
2
TX1322 TLV-1 transformer
80ºC
3
TX1322 TLV-1 transformer
80ºC
Figure 2-3
Critical Temperature Spot