background image

This document may be photocopied for personal use. 

Visit our website at http://www.emersonclimate.com for the latest technical documentation and updates.

Join Emerson Retail Solutions Technical Support on Facebook. http://on.fb.me/WUQRnt

For Technical Support call 770-425-2724 or email [email protected]

The contents of this publication are presented for informational purposes only and they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described 

herein or their use or applicability. Emerson Climate Technologies Retail Solutions, Inc. and/or its affiliates (collectively “Emerson”), reserves the right to modify the designs or specifications of such products 

at any time without notice. Emerson does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any product remains 

solely with the purchaser and end-user.

Document Part # 026-4159 Rev 2

Page 5 of 5

Step 4: Setting Up the Site Supervisor Web Server 

The default Web Port on the System Values screen for the Site Supervisor is 80, but if this port is changed to another value, 
you must add that value to the IP Address 192.168.1.250. For example, if the port value is changed to 

1025

, the IP Address in 

section 

Setting Up the Browser Startup Page

,

 Step 3

 would be 192.168.1.250

:1025

.

To Change to a Different Site Supervisor IP Address

1. Press top left corner of the Display to open the login screen and login using 

admin/admin

.

2. Tap 

Proceed

 and the Browser settings page will open. 

3. Repeat the procedure in 

Step 3: Setting Up the Browser Startup Page 

section.

To Change the Display’s Network Configuration

1. Press the top left corner of the Display to open the login screen and login using 

admin/admin

.

2. Tap 

Proceed 

and the Browser settings page will open. 

3. Repeat the procedure in 

Step 2: Setting Up the Display Network Configuration 

section and begin at 

part 3

.

Web Port Setup on the Site Supervisor System Values Screen

Summary of Contents for 818-7235

Page 1: ...er Service at 770 425 2724 Display Connections and Specifications General Warnings and Safety Precautions The display should not be used for purposes different from those described in this guide It cannot be used as a safety device When using an external power supply it is necessary to separate the power of the device from the rest of the electrical devices connected inside the electrical panel Di...

Page 2: ...Blocks XCFR2 manufactured by Weidmuller Inc Cat No BLZ 5 08 torque 4 5 lb in Installation and Fixing Bracket Installation Mounting Dimensions Model A B C H L 818 7235 176mm 06 90 136mm 05 35 47mm 01 85 147mm 05 79 187mm 07 36 818 7230 271mm 10 66 186mm 07 32 56mm 02 20 197mm 07 75 282mm 11 10 24V Power Supply WARNING Extra low voltage power supply Limited power source Installation Mounting Bracket...

Page 3: ...must enable DHCP or set up a Static IP Address on the Display Step 2 below Step 2 Setting Up the Display Network Configuration Access Display Network Configuration 1 Power up the Display with 24VDC power supply not included 2 Wait for the browser login screen to appear Login with username password admin admin The Chrome settings page will appear Note that a username password of user user is for vi...

Page 4: ... sitesupervisorIP in the Enter URL field but if you are directly connected to the Site Supervisor the IP Address must be http 192 168 1 250 The firmware should already be preloaded with this IP address 3 Tap Enter and Close on the keyboard to see full screen Tap OK to save 4 Manually cycle power to the Display only do not cycle power to the Site Supervisor 5 The Display will boot up and the browse...

Page 5: ...oduct remains solely with the purchaser and end user Document Part 026 4159 Rev 2 Page 5 of 5 Step 4 Setting Up the Site Supervisor Web Server The default Web Port on the System Values screen for the Site Supervisor is 80 but if this port is changed to another value you must add that value to the IP Address 192 168 1 250 For example if the port value is changed to 1025 the IP Address in section Se...

Reviews: