MODBUS Termination Blocks
Default Setting Values • 29
doA
Door open alarm delay
0 to 255 min
15
Pr1
nPS
Number of activation of pressure switch
0 to 15
15
Pr2
Odc
Compress status when open door
no
;
Fan
;
CPr
;
F_C
F-C
Pr2
rrd
Regulation restart with door open alarm
n
–
Y
y
Pr2
HES
Differential for Energy Saving
(-30°C to 30°C) (-54°F to 54°F)
0
Pr2
Hur*
Current hour
0 to 23
-
Pr1
Min*
Current minute
0 to 59
-
Pr1
dAY*
Current day
Sun to SAt
-
Pr1
Hd1*
First weekly holiday
Sun to SAt – not used
not used
Pr1
Hd2*
Second weekly holiday
Sun to SAt – not used
not used
Pr1
ILE*
Energy Saving cycle start during workdays
0 to 23 hr 50 min
0.0
Pr1
dLE*
Energy Saving cycle length during workdays
0 to 24 hr 00 min
0
Pr1
ISE*
Energy Saving cycle start on holidays
0 to 23 hr 50 min
0.0
Pr1
dSE*
Energy Saving cycle length on holidays
0 to 24 hr 00 min
0
Pr1
Ld1*
1
st
workdays defrost start
0 to 23 hr 50 min - not used
6.0
Pr1
Ld2*
2
nd
workdays defrost start
0 to 23 hr 50 min - not used
13.0
Pr1
Ld3*
3
rd
workdays defrost start
0 to 23 hr 50 min - not used
21.0
Pr1
Ld4*
4
th
workdays defrost start
0 to 23 hr 50 min - not used
not used
Pr1
Ld5*
5
th
workdays defrost start
0 to 23 hr 50 min - not used
not used
Pr1
Ld6*
6
th
workdays defrost start
0 to 23 hr 50 min. - not used
not used
Pr1
Sd1*
1
st
holiday defrost start
0 to 23 hr 50 min - not used
6.0
Pr1
Sd2*
2
nd
holiday defrost start
0 to 23 hr 50 min - not used
13.0
Pr1
Sd3*
3
rd
holiday defrost start
0 to 23 hr 50 min - not used
21.0
Pr1
Sd4*
4
th
holiday defrost start
0 to 23 hr 50 min - not used
not used
Pr1
Sd5*
5
th
holiday defrost start
0 to 23 hr 50 min - not used
not used
Pr1
Sd6*
6
th
holiday defrost start
0 to 23 hr 50 min - not used
not used
Pr1
Adr
Serial address
1 to 247
1
Pr2
pbC
Kind of probe
Pt1000; ntc
ntc
Pr2
onF
ON/OFF key enabling
not used,
oFF
;
ES
not used
Pr2
dP1
Room probe display
--
-
Pr1
dP2
Evaporator probe display
--
-
Pr1
dP3
Third probe display
--
-
Pr1
dP4
Fourth probe display
--
-
Pr1
rSE
Real set
actual set
-
Pr2
rEL
Software release
--
2.6
Pr2
Ptb
Map code
--
-
Pr2
Label
Name
Range
Value
Level
Table 19-1
- Default Setting Values (
*
Only for models with real time clock (RTC),
2
Only for XR75CX with X-REP output)