- 13 -
The hot air exhaust hose is not connected
or blocked.
Connect or clean the hot air exhaust
hose.
Temperature setting is too high.
Reset the temperature.
Air inlet or outlet is blocked.
Clean the air inlet or outlet.
Noisy
The ground is not level or not flat enough.
Place the appliance on a flat, level
surface if possible.
The sound comes from the flowing of the
refrigerant inside the appliance.
It is normal.
Code “E2” on the
digital display
Room temperature sensor failed.
Replace the room temperature sensor.
Contact authorized service technician
for repair.
Code “E3” on the
digital display
Evaporator temperature sensor failed.
Replace evaporator temperature sensor.
Contact authorized service technician
for repair.
Code
“E4” on the
digital display
Water-full warning
Drain out the water.
TECHNICAL DATA
Below data for your operating reference
Model
PAC-125153.1
Rated voltage
220-240V
Rated frequency
50Hz
Rated input
950W
Rated current
4.2A
Cooling capacity
9000BTU
Moisture removal (L/H)
1.0
Air flow
300m³/h
Max. transmitting power
20dBm
Frequency range
2412 - 2472MHz
We, Emerio, declare under our sole responsibility that the product: PAC-125153.1 is in conformity with the
essential requirements and other relevant requirements of the RED Directive (2014/53/EU)
The complete CE declaration is available at the following address: www.emerio.eu
ERP INFORMATION
Value
Trademark
Emerio
Model identification
PAC-125153.1
Sound power (cooling)
64.3dB(A)
Name of refrigerant
R290
Rated power input for cooling (kW)
0.95
Rated energy efficiency ratio
2.6
GWP (kgCO
2
eq)
3
Energy efficiency class
A
Energy consumption
for double ducts appliances
(kWh/h)
N.A
Energy consumption
for single duct appliances
(kWh/h)
0.96