Too low temperature - The BMS prevents the battery from being
charged at temperatures below -10°C.
▪
Short circuit - The BMS switches the battery off if the terminals are
shorted.
▪
Our batteries have a cell balancing function built into the BMS.
Because the cells are never 100% identical, this system ensures
that the cells remain balanced and that no major differences in cell
voltages can arise due to the discharge and charging.
The PowerXtreme X75/X125 are equipped with Bluetooth technology that
allows monitoring of the battery and switching it on and off via an App.