![EmergoPlus PowerXtreme X125 User Manual Download Page 16](http://html1.mh-extra.com/html/emergoplus/powerxtreme-x125/powerxtreme-x125_user-manual_2400120016.webp)
User manual PowerXtreme X75/X125
E18-X75X125-EN00
www.emergoplus.com
Page 16 of 25
▪
Switch off all loads and charging equipment before you start
connecting.
▪
Use proper cabling of sufficient cross-section and correctly
dimensioned terminals and battery terminals. Tighten all
connections securely. Recommended tightening torque for M6 is
9.9 - 14 Nm. Do not use too great a tightening torque, as this can
lead to irreparable damage to the LiFePO4 battery.
▪
If you use screws to connect consumers instead of the supplied
battery terminals, make sure that these screws are not longer than
10mm.
PAY ATTENTION!
The supplied battery poles have different
diameters, the thinnest is for the negative pole,
the thickest for the positive pole.
Figure 2. Difference diameter of + and - pole