![EmergoPlus PowerXtreme X125 User Manual Download Page 13](http://html1.mh-extra.com/html/emergoplus/powerxtreme-x125/powerxtreme-x125_user-manual_2400120013.webp)
User manual PowerXtreme X75/X125
E18-X75X125-EN00
www.emergoplus.com
Page 13 of 25
Temperature of the cell pack. If the temperature is too low or too high, a
safety device is activated.
Cycle life keeps track of how often the battery has been discharged by 80%.
For example, from 90% SOC to 10% SOC is a cycle. Also, from 70% SOC to
empty then charging to 100% and empty to 90% is a cycle.
System Info tab
System info contains messages about events that occurred during the
charging or discharge process. This refers to the following events:
▪
Short circuit
▪
Lift up short circuit
▪
High temperature at charging
▪
High temperature at discharge
▪
Low temperature at charging
▪
Low temperature at discharge
▪
Overcurrent when charging
▪
Too much current when discharged
▪
High Voltage
▪
Low Voltage
▪
Temperature/Voltage/Current back to normal
▪
Display remaining charge time
The Buy Info tab
Please provide the contact details of EmergoPlus.
PAY ATTENTION!
It is possible that the app displays a value that is
too low for the SOC (charge status) when the
battery has not been used for a longer period of
time. Once you have charged the battery, the SOC
display will be correct again.