EES-401 Series Ultrasonic Energy Meter
Revision: 3.0.1
Page 80 of 90
$0008
40009
Integer part of flow negative
accumulation (low half word)
integer
$0009
40010
Fractional part of flow negative
accumulation
16-bit signed
integer
The value changes according to
the change of the flow unit, and
the number is expanded by
10000 times before output, so the
real value needs to be reduced by
the same multiple
$000A
40011
Integer part of flow net
accumulation (high half word)
32-bit signed
integer
$000B
40012
Integer part of flow net
accumulation (low half word)
$000C
40013
Fractional part of flow negative
accumulation
16-bit signed
integer
The value changes according to
the change of the flow unit, and
the number is expanded by
10000 times before output, so the
real value needs to be reduced by
the same multiple
$000D
40014
Device serial number
characters 1 and 2
String
$000E
40015
Device serial number
characters 3 and 4
$000F
40016
Device serial number
characters 5 and 6
$0010
40017
Device serial number
characters 7 and 8
$0011
40018
Upstream signal strength (high
half word)
32-bit floating
point number
$0012
40019
Upstream signal strength (low
half word)
$0013
40020
Downstream signal strength
(high halfword)
$0014
40021
Downstream signal strength
(low halfword)
$0015
40022
Signal quality
16-bit signed
integer
$0016
40023
Outer diameter (high half
character)
32-bit floating
point number
$0017
40024
Outer diameter (low half
character)
$0018
40025
Wall thickness (high half
32-bit floating