11. “Pumps Activities”
From “Menu Calibration” choose “Pumps activities”. This menu allows to manually operate one or both the pumps for a
settable time.
Move on “Mode” then press wheel. Choose “Man. Pump1” for manually operate pH pumps or “Man. Pump2” for Cl
pump.
Press wheel to move cursor on “TIME”
fi
eld. Once here, choose a working time between 0 (disabled) or 199 minutes.
Move on “EXIT”, then press wheel.
Choose “YES” to save changes. Exit from main menu. Main display will show a countdown including the selected pump
(left for pH pump, right for Cl pump). To stop this countdown go back to “Pump activities” menu and choose “ON” as
working mode or wait until countdown ends.
This function can be used for priming purposes.