Expanded operating temperature restrictions
l
Do not perform a cold startup below 5°C.
l
The operating temperature specified is for a maximum altitude of 3050 m (10,000
ft).
l
Redundant power supply units are required.
l
Non-EMC qualified peripheral cards and/or peripheral cards greater than 25 W are
not supported.
Thermal restrictions
The following table lists the configurations required for efficient cooling.
The following table describes the configuration required for efficient cooling.
Table 31 Thermal restrictions configuration
Config
# of processor Heatsink
Proc/
DIMM
blank
DIMM blanks Max number of
DIMM blanks
Fan
2.5 inch
hard drives
x 10
1
One 1U
standard heat
sink for CPU
≤ 165 W
Not required Required for
processor 1
11 blanks
Five standard fans
One 1U 2-pipe
heat sink for
CPU=200/20
5 W
Required
Eight high
performance fans
2
Two 1U
standard heat
sink for CPU
≤ 165 W
Not required
Eight standard fans
Two 1U 2-pipe
heat sink for
CPU=200/20
5 W
Required
22 blanks
Eight high
performance fans