Table 39 SRDF 2-site solutions (continued)
Solution highlights
Site topology
SRDF and VMware Site Recovery Manager
Completely automates storage-based disaster
restart operations for VMware environments in
SRDF topologies.
l
The EMC SRDF Adapter enables VMware Site
Recovery Manager to automate storage-based
disaster restart operations in SRDF solutions.
l
Can address configurations in which data are
spread across multiple storage arrays or SRDF
groups.
l
Requires that the adapter is installed on each
array to facilitate the discovery of arrays and to
initiate failover operations.
l
Implemented with:
n
SRDF/S
n
SRDF/A
n
SRDF/Star
n
TimeFinder
For more information, see:
l
Using EMC SRDF Adapter for VMware Site
Recovery Manager Tech Book
l
EMC SRDF Adapter for VMware Site Recovery
Manager Release Notes
IP Network
SAN Fabric
SAN Fabric
SRDF mirroring
SAN Fabric
SAN Fabric
Site A, primary
IP Network
Site B, secondary
vCenter and SRM Server
Solutions Enabler software
Protection side
vCenter and SRM Server
Solutions Enabler software
Recovery side
ESX Server
Solutions Enabler software
configured as a SYMAPI server
SRDF multi-site solutions
The following table describes SRDF multi-site solutions.
Table 40 SRDF multi-site solutions
Solution highlights
Site topology
SRDF/Automated Replication
(SRDF/AR)
l
Combines SRDF and
TimeFinder to optimize
bandwidth requirements and
provide a long-distance
disaster restart solution.
l
Operates in 3-site solutions
that use a combination of
SRDF/S, SRDF/DM, and
TimeFinder.
SRDF/S
Site A
Site C
Host
Site B
R1
R2
Host
TimeFinder
R1
TimeFinder
SRDF adaptive
copy
R2
Remote replication solutions
SRDF multi-site solutions
105
Summary of Contents for VMAX 100K
Page 1: ...EMC VMAX3 Family Product Guide VMAX 100K VMAX 200K VMAX 400K with HYPERMAX OS REVISION 6 5 ...
Page 20: ...Preface 20 Product Guide VMAX 100K VMAX 200K VMAX 400K with HYPERMAX OS ...
Page 46: ...VMAX3 with HYPERMAX OS 46 Product Guide VMAX 100K VMAX 200K VMAX 400K with HYPERMAX OS ...
Page 72: ...Open systems features 72 Product Guide VMAX 100K VMAX 200K VMAX 400K with HYPERMAX OS ...
Page 82: ...Provisioning 82 Product Guide VMAX 100K VMAX 200K VMAX 400K with HYPERMAX OS ...
Page 158: ...Remote replication solutions 158 Product Guide VMAX 100K VMAX 200K VMAX 400K with HYPERMAX OS ...
Page 186: ...Mainframe Error Reporting 186 Product Guide VMAX 100K VMAX 200K VMAX 400K with HYPERMAX OS ...
Page 200: ...Licensing 200 Product Guide VMAX 100K VMAX 200K VMAX 400K with HYPERMAX OS ...