9. Technical Specifications 

 
For model with 3 Phase in 1 Phase out 

Tower model (with LCD display) 

8K31 

10K31 

12K31 

15K31 

20K31 

Capacity (VA) 

8000VA 

10000VA 

12000VA 

15000VA 

20000VA 

Capacity  

Capacity (W) 

5600W 

7000W 

8400W 

10500W 

14000W 

208/360V, 220/380V, 230/400V, 240/415V(3

Ф

5W) 

Load Capacity 

Voltage/Range 

Load Capacity 

208~241V 

0~25% 

242~276V 

0~40% 

Voltage/Load 

277~311V 

0~75% 

312~478V 

0~100% 

Input 

Frequency 

50/60 Hz Auto Sensing 

Voltage (on battery)   

100V, 110V, 115V, 120V / 208V, 220V, 230V, 240V +/-2% (Selectable Output Voltage) 

Frequency (on battery) 

50 / 60 Hz +/-0.5%   

Transfer Time   

0 ms   

Overload Recovery   

Auto transfer to UPS   

High Efficiency mode 

(AC to AC)   

> 97 %   

UPS Design 

Technology  

On-Line / Fully digitized microprocessor controlled   

Output Wave Form   

Sine wave   

Harmonic distortion   

< 3% of T.H.D. at linear load   

Output  

Crest Factor   

3 : 1   

Surge Protection   

IEC61000-4-5 level 3   

Overload Protection   

125% for 1 minutes and 150% for 10 seconds 130% for 10 seconds and 150% for 1.5 

seconds (On-battery)   

Protection 

and Filtering   

Short Circuit Protection 

UPS output cut off immediately or input fuse / circuit breaker protection   

Visual Display (LED 

model)  

UPS on(green), line-mode(green), battery mode(yellow), bypass(yellow), fault(red)   

Visual Display (LCD 

model)  

Input / output voltage, input / output frequency, on-line mode, back up mode, battery 

capacity, load level   

Audible Alarm (Battery 

back-up)  

Beep every 5 sec   

UPS Fault   

Continuous beeping sound and LCD display   

System 

Display/ 

Warning 

Communication  

RS-232 Serial Port and USB   

Type  

Sealed, maintenance-free lead acid batteries   

DC Voltage (V) Battery 

(Tower )   

240V / 

12V7.2AH x 

20  

240V / 

12V9AH x 20   

240V / 

12V7.2AH x 20 x 

2SET  

240V / 

12V7.2AH x 

20 x 2SET 

240V / 

12V9AH x 20 

x 2SET   

Typical Recharge Time 

to 90% Full   

4 hours 

Management  

Self-test, adjustable battery transfer points and alarm settings   

Battery Protection   

Cut off without draining any current when battery is low   

Cold Start (DC start)   

YES  

Battery 

Back Up Time (Tower 

model)  

About 

4~

6 min Full load / 

10~

15min Half load   

Input Inlet   

Hardwire  

Receptacles  

Hardwire  

Dimensions W x D x H 

mm (inch) W/O ISOTR 

257 x 690 x 715   

(10.1" x 27.2" x 28.1")   

342 x 690 x 878 

(13.5"x27.2"x34.6") 

342 x 863 x 905   

(13.5" x 34.0" x 35.6")   

Net Weight kg (lb) W/O 

ISOTR  

80.0 (176.0)   

176.5 (388.3) 

175.0 (385.0)   

Shipping Weight kg (lb) 

W/O ISOTR   

101.5 (223.3)   

206.5 (454.3) 

196.0 (432.3)   

Dimensions W x D x 

H mm (inch) W/ 

ISOTR  

342 x 690 x 715   

(13.4" x 27.2" x 28.1")   

342 x 690 x 878 

(13.5"x27.2"x34.6") 

342 x 863 x 905   

(13.5" x 34.0" x 35.6")   

Physical 

Net Weight kg (lb) 

W/ ISOTR   

130.0 (286.0)   

176.5 (388.3)   

225.0 (495.0)   

 

29

Shipping Weight kg 

(lb) W/ ISOTR   

151.5 (333.3)   

206.5 (454.3)   

246.5 (542.3)   

Operating 

Temperature  

0~40

°

C / 32~104

°

F  

Storage 

Temperature  

-20~50

°

C / -4~122

°

F  

Altitude  

3,500 meters max   

Audible Noise (1 

meter from surface) 

< 55 dB   

Environment 

Relative Humidity   

0 ~ 95% humidity, non-condensing   

 
For Tower model 

Tower model (with LCD display)   

VGD-4000 

VGD5000 

VGD-6000  

VGD-8000  

Capacity (VA)   

4000VA 

5000VA 

6000VA  

8000VA  

Capacity 

Capacity (W)   

2800W 

3500W 

4200W  

5600W  

Voltage (on battery) 

208V, 220V, 230V, 240V +/-2% (Selectable Output Voltage) For 4K / 5K / 6K 

 

100V, 110V, 115V, 120V / 208V, 220V, 230V, 240V +/-2% (Selectable Output Voltage) 

For 6K / 8K with output isolation transformer 

 

Frequency (on 

battery)  

50 / 60 Hz +/-0.5%   

Transfer Time   

0 ms   

Overload Recovery 

Auto transfer to UPS   

High Efficiency 

mode (AC to AC)   

> 95 % 

> 97 %   

UPS Design 

Technology  

On-Line / Fully digitized microprocessor controlled   

Output Wave Form 

Sine wave   

Harmonic distortion 

< 3% of T.H.D. at linear load   

Output  

Crest Factor   

3 : 1   

Surge Protection 

 

IEC61000-4-5 level 3   

Overload 

Protection  

125% for 1 minutes and 150% for 10 seconds (On-line) 130% for 10 seconds and 150%   

for 1.5 seconds (On-battery)   

Protection and 

Filtering 

Short Circuit 

Protection  

UPS output cut off immediately or input fuse / circuit breaker protection   

Visual Display 

(LED model)   

UPS on(green), line-mode(green), battery mode(yellow), bypass(yellow), fault(red)   

Visual Display 

(LCD model)   

Input / output voltage, input / output frequency, on-line mode, back up mode, battery 

capacity, load level   

Audible Alarm 

(Battery back-up)   

Beep every 5 sec   

UPS Fault   

Continuous beeping sound and LCD display   

System/Display

/Warning  

Communication  

RS-232 Serial Port and USB   

Type  

Sealed, maintenance-free lead acid batteries   

DC Voltage (V) 

Battery (Tower )   

120V / 12V7AH 

 x 10  

120V / 12V9AH   

x 10   

240V / 12V7.2AH   

x 20   

240V / 12V7.2AH 

 x 20  

Typical Recharge 

Time to 90% Full   

4 hours 

Management  

Self-test, adjustable battery transfer points and alarm settings   

Battery Protection   

Cut off without draining any current when battery is low   

Cold Start (DC 

start)  

YES  

Battery 

Back Up Time 

(Tower model)   

4 min. Full load / 

10 min. Half load 

5 min. Full load / 

13 min. Half load 

About 

4~

6 min Full load / 

10~

15min Half load 

Input Inlet 

Hardwire  

Receptacles  

IEC C13*8 ; C19*2 

Hardwire  

Physical 

Dimensions W x D 

x H mm (inch) W/O 

ISOTR  

257*537*440 

(10.1”x21.1”x17.3”) 

257 x 590 x 570 

(10.1"x23.2"x22.4")  

257 x 690 x 715 

(10.1" x 27.2" x 

28.1")  

Summary of Contents for 4K VA 20K VA UPS

Page 1: ...ced by harmful interference from the equipment it is recommended to use one of the following preventive measures z Place the receiving antenna in a separate location or orientation z Ensure a greater...

Page 2: ...ide Refer servicing to qualified service personnel CAUTION Non isolated Battery supply Risk of electric shock battery circuit is not isolated from AC input hazardous voltage may exist between battery...

Page 3: ...lation must be carried out in accordance with this manual Electrical installations must also carefully follow local legislation and regulations Only qualified personnel should conduct these installati...

Page 4: ...ions of the batteries sends any forewarnings if replacement is needed Otherwise every 30 days of normal mode operation a battery discharge test is performed and any problems reported on the LCD displa...

Page 5: ...e very hazardous to the operator 5 4 Storage Please adhere to the following instructions if the UPS is not installed immediately z Store the equipment as is in its original packing and shipping carton...

Page 6: ...6 5 2 Rear panel views 4K 5KVA 120VDC Rear panel 7 6KVA Rear panel Without ISO...

Page 7: ...8 6KVA Rear panel With ISO 9 8K 10KVA Rear panel Without ISO...

Page 8: ...10 8K 10 KVA Rear panel With ISO 11 12KVA Rear panel ISO and With ISO...

Page 9: ...nstalled z Be aware of UPS parameters and changing the Battery pack quantity when using the external battery cabinets see chapter 7 2 Installing UPS z Ensure that the installation site has all electri...

Page 10: ...connections be used use connections according to chapter 6 of the manual provided with that option The connections can be referred to on the rear panel z The installation is now complete b removable j...

Page 11: ...munications cards It can be used parallel with either the RS232 or USB ports Currently there are two cards available for the optional interface slot An SNMP WEB card allows management and monitoring o...

Page 12: ...tput power has commenced and the LCD will display Line mode z Switch on the loads Shutting down the UPS z Shut down and turn off the loads z Push the ON OFF button on the front panel for two seconds T...

Page 13: ...rol panel Normal display The UPS status is shown in normal display mode From here you have a choice to go to UPS meters display and the Setting display by pushing the button UPS meters display Various...

Page 14: ...t Input Voltage range when bypass is available 10 10 15 15 20 10 15 Free Run Mode Free Run Set Select if UPS can run in Free run mode unsynchronized ON OFF ON Bypass Enable Disable at Free run mode By...

Page 15: ...tness any alarm indication on the control panel Alarm indicators The UPS gives the following audible alarms z If UPS is on battery and the ON BATTERY LED is on UPS will beep every 5 seconds z If the b...

Page 16: ...Low Output Voltage Constant beep Low output voltage Call the Local dealer Bus Fault 2 Beeps per second High internal DC bus Voltage Turn off protected loads Turn off UPS and call your local dealer Si...

Page 17: ...h W ISOTR 342 x 690 x 715 13 4 x 27 2 x 28 1 342 x 690 x 878 13 5 x27 2 x34 6 342 x 863 x 905 13 5 x 34 0 x 35 6 Physical Net Weight kg lb W ISOTR 130 0 286 0 176 5 388 3 225 0 495 0 29 Shipping Weigh...

Page 18: ...lf test adjustable battery transfer points and alarm settings Battery Battery Protection Cut off without draining any current when battery is low 31 Cold Start DC start YES Back Up Time Tower model Ab...

Page 19: ...Receptacles Hardwire Dimensions W x D x H mm inch TBD 428 597 260 18 9 23 5 10 2 428 658 260 18 9 25 9 10 2 Net Weight kg lb TBD 86Kg 189lb 110Kg 242lb Physical Shipping Weight kg lb TBD 100Kg 220lb 1...

Page 20: ...MPONENT INCLUDING 3U UPS 3U BATT CABINET FRONT VIEW REAR VIEW 35 2 UPS REAR PANEL COMPONENTS H TERMINAL BLOCK I BREAKER J EXTERNAL BATTERY CONNECTOR K BYPASS SWITCH L SNMP SLOT M RS232 EPO N TVSS O US...

Page 21: ...TION a Remove the original right side panel and take apart the control panel unit Then assemble the blank right side panel b Connect the Control panel unit and Remote control port from rear side 37 c...

Page 22: ...ge the position of the two mounting brackets to mount the 3U rack mount in a 23 inch EIA 310 C standard rack 3 Tower installation a Move the mounting brackets from the front to the side and attach the...

Page 23: ...ting brackets from the front to the side and attach the brackets by screws Then mount the UPS to the wall as the below pictures shown 5 Installation with rear Bracket We can use bracket to support the...

Reviews: