Fig. 2
2.3 Electrical connection
DANGER!
The appliance must be connected to the mains by a qualified
professional, who is familiar with and adheres to the local
requirements and supplementary regulations of your electricity
supplier.
All electrical work must be carried out by a qualified professional. Do
not modify the energy supply. The connection must be carried out in
accordance with the current local and legal regulations
Instructions for the installer (qualified professional)
The appliance is designed to be connected to a 230V-50Hz electricity supply. Total
power absorbed is 3000W. The cable used for connection must have a cross
section of 1.5 mm
2
. The direct connection to the mains supply must have a double
pole switch with a minimum rating of 250V, 20A. The switch must not brake the
yellow-green earth cable at any point.
The cable must be placed in such a way that it cannot touch a high temperature
area at any point after installation and connection.