USER MANUAL

STRIVE FOR CLEAR WATER

www.emauxgroup.com

SINGLE ELEMENT CARTRIDGE FILTER

Installation and Operation Manual

EMAUX WATER TECHNOLOGY CO., LTD

Models:  ICF 100 / 

ICF 150  ICF 200

EMFI22021501

Summary of Contents for ICF 100

Page 1: ...USER MANUAL STRIVE FOR CLEAR WATER www emauxgroup com SINGLE ELEMENT CARTRIDGE FILTER Installation and Operation Manual EMAUX WATER TECHNOLOGY CO LTD Models ICF 100 ICF 150 ICF 200 EMFI22021501 ...

Page 2: ...repositioning valve s and before beginning the assembly disassembly or any other service of the circulating system 1 Turn the pump OFF and shut OFF any automatic controls to ensure the system is NOT inadvertently started during the servicing open the manual air release valve Wait until all pressure is relieved 3 Whenever installing the filter closure follow the filter closure warnings exactly 4 On...

Page 3: ...exceed the maximum operating pressure of the system components Exceeding these limits could result in a component failing under pressure This instantaneous release of energy can cause the closure to separate and could cause severe personal injury or death if they were to strike a person This product should be installed and serviced only by a qualified pool professional 1 The filter system should b...

Page 4: ...re reading turn the outer dial START arrow marker to the pressure gauge pointer position When the pressure rises to or above the CLEAN FILTER marker it is time to clean or replace your filter cartridge elements By recording the initial starting pressure with clean filter elements a determination can be made when the filter cartridge elements should be replaced rather than cleaned After the filter ...

Page 5: ...en hose After hosing the cartridge for best results carefully brush the pleated surface to remove fine particles Do not pressure wash as it can damage the filter element You may find some debris on the cartridge pleats which may not have been removed with hosing 4 4 FILTER REASSEMBLY INSTRUCTIONS 4 4 1 RE INSTALLING CARTRIDGES 1 Remove filter tank sealing O Ring 2 With a clean cloth wipe the lower...

Page 6: ...0 to 400 ppm 0 2 ppm Maximum 1 0 to 3 0 ppm 60 to 80 ppm 4 5 REMOVING THE MANUAL AIR RELEASES VALVE The filter comes with a preinstalled manual air relief valve Servicing the Manual Air Release Valve MAR should be carried out by pool professionals only by carefully following the instructions 1 Turn off all system circulation pumps and all electric power on the equipment pad 2 Set all system valves...

Page 7: ...tack or g as a result of service by anyone other than Emaux authorized reseller or authorized agent EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY EMAUX MAKES NO OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE EMAUX EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY ANY IMPLIED WARRANTIES THAT MAY BE...