emaux 9140404 Installation & Operation Manual Download Page 8

P7    MAINTAINING YOUR FILTER 

4. MAINTAINING YOUR FILTER 

This product should be installed and ser viced only by qualified pool professional.

3. Monitor the pressure from time to time, when the pressure reading is over the Clean Filter arrow, follow step 

4.2 to clean filter cartridge elements.

Replace a new filter cartridge element. 

You should replace a new filter cartridge element:

1. After cleaning the filter element, if the pressure is: 

   a.25 psi higher than the initial start ready, or 

   b.the pressure reading is over 40 psi.

2. When the filter element is broken, or the layer peers off.

3. When the pressure or flow rate is below the desired rate of the system. 

1. Turn off all system circulation pumps and all-electric power on the equipment pad. 

2. Set all system valves in a position to prevent water flow to the filter.

3. The air relief valve OPEN. 

4. Remove the drain plug and let water flow out from the filter.

5. Using wrenches,loosen and remove the clamp by unscrewing the clamp nut and the bolt.

6. Holding both ends of the clamp carefully then spread the clamp ends.Lifting the clamp over the upper body.   

Do  not drop the ring and do not strike the clamp with metal tools,the clamp could be damaged.

7. Lift off the upper body. Do not hold the pressure gauge to lift the upper body.

4.1 FILTER DISASSEMBLY INSTRUCTION

4.2 REMOVING CARTRIDGES

1. Remove the filter cartridge elements by using a slight rocking motion and lifting.

2. Clean filter cartridge elements.

4.3 CLEANING CARTRIDGES

The Cartridge filter element can be cleaned by washing inside and outside with a garden hose. After hosing the 

cartridge, carefully brush the pleated surface to remove fine particles. Do not pressure wash as it can damage 

the filter element.

You may find some debris on the cartridge pleats, which may not have been removed with hosing

Figure 5

Top manifold plate

Sealing O ring

Bottom body

Sealing surface

Summary of Contents for 9140404

Page 1: ...USER MANUAL MULTI ELEMENT CARTRIDGE FILTER Installation and Operation Models ICF230 330 430 530 680 ICF ICF ICF ICF EMFI22050603...

Page 2: ...4 4 FILTER REASSEMBLY INSTRUCTION 4 4 1 RE INSTALLATION CARTRIDGES 4 4 2 CLEAN SEAL RING AND SEAL SURFACE 4 4 3 BODY AND CLAMP REASSEMBLY 4 4 4 VACUUMING POOL 4 5 REMOVING THE AIR RELIEF VALVE 4 5 1...

Page 3: ...g your dealer or a qualified pool technician 2 Read the entire Installation Operation Manual before attempting to use service or adjust the pool filtering system 2 Before repositioning valve s and bef...

Page 4: ...o not locate pump control over near the filter Due to the potential risk that can be involved it is recommended that the pressure test be kept to the minimum time required by the local code Do not all...

Page 5: ...be installed and serviced only by a qualified pool professional 1 The filter system should be installed on a level concrete slab or another rigid base Select a well drained and vented area one that d...

Page 6: ...components Clamp unit doing assembly metal reinforced seal Non tighten clamp components may fail in use and cause explosive component separation Verify that upper and lower filter bodies are properly...

Page 7: ...m pump do not stand over or near the filter If water leakage appears at the clamp Turn off all system circulation pumps and all electrical power Do not return to the filter until all water leakage has...

Page 8: ...4 Remove the drain plug and let water flow out from the filter 5 Using wrenches loosen and remove the clamp by unscrewing the clamp nut and the bolt 6 Holding both ends of the clamp carefully then spr...

Page 9: ...a clean cloth wipe the lower filter body seal surface and clean seal of all dirt and debris Do not use a solvent 3 With a clean cloth wipe the upper body seal surface 4 4 2 CLEAN SEAL RING AND SEAL SU...

Page 10: ...all water leakage has stopped 5 Grasp the handle at the top of the upper filter body turn counterclockwise until the Relief valve unit is aligned with the UNLOCK position on the upper filter body and...

Page 11: ...EMEDY 1 Check skimmer and pump strainer baskets for debris 2 Check for restrictions in intake and discharge lines 4 Clean Filter Cartridges 1 Check for algae in the pool and super chlorinate as requir...

Page 12: ...1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 1 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Handle Air relief valve O ring d14 3 2 5 O ring d6 3 5 Air relief val...

Page 13: ...he use of parts not manufactured or sold by Emaux e by modification of the product f as a result of war or terrorist attack or g as a result of service by anyone other than Emaux authorized reseller o...

Page 14: ...YOUR PREMIER SUPPLIER www emauxgroup com EMAUX WATER TECHNOLOGY CO LTD...