P7 IMPORTANT SAFETY INSTRUCTIONS
INSTALLATION P8
4. IMPORTANT SAFETY INSTRUCTIONS
The user guide you are holding includes essential information on the
safety measures to be implemented for installation and start-up.
Therefore, the installer as well as the user must read the instructions
before beginning installation and start-up. Keep this manual for future
reference.
1. A protective device is to be installed in the fixed wiring.
2. This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensor y or mental capabilities or lack of experience and knowledge
if they have been given super vision or instruction concerning use of the appliance in a
safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without
super vision.
3. The appliance shall be installed in accordance with national wiring regulations means
for disconnection must be incorporated in the fixed wiring in accordance with the
wiring rules. A disconnected incorporated in the fixed wiring is to be provided.
4. The pump is to be supplied through a residual current device (RCD) or Ground Fault
Circuit Interrupt (GFCI) having a rated residual operation current not exceeding 30mA.
Correct disposal of this product
This symbol on the product, or in its packaging, indicates that this product may not be
treated as household waste. Instead, it should be taken to the appropriate waste
collection point for the recycling of electrical and electronic equipment. By ensuring
this product is disposed of correctly, you will help prevent potential negative
consequences for the environment and human health, which could other wise be caused
by the inappropriate waste handling of this product. For more detailed information
about the recycling of this product, please contact your local council, your household
waste disposal ser vice, or the shop where you purchased the product.
5.
INSTALLATION
5.1 PIPING
4. Secure the pump to the base with screws or bolts to limit the vibration and the stress
on the pipe or the joints.
5. Leave enough space for gate valves in suction and discharge piping, if required.
6. Ensure there is enough clearance for pre-filter basket & Lid open and motor
ventilation.
7. Connect the suction and discharge pipe to the
outlet and inlet of the swimming pool.
8. Make sure that floor drainage is adequate to
prevent flooding.
9. Make sure that the pump and piping are
accessible for ser vicing.
Note: The pump suction and discharge connections are mounded in
thread stops, DO NOT tr y to screw the pipe beyond these stops.
The two sets 1.5” union adaptor are universal design for metric and
imperial PVC pipe connection.
5.2 ELECTRICAL WIRING
This power pump demand licensed or certified electrician or
qualified pool installer to ensure there is adequate protection
between the pump motor and mains power supply according to
individual countries safety code.
The pump has power cord with plug attached on the plug, plug
it to a power socket with circuit breaker to isolate the motor from the mains power for
over load protection. The circuit breaker rating should refer to the electrical specification
of individual pump working voltage and power.
The power has to be with a Residual Current Device (RCD) or Ground Fault Circuit
Interrupt (GFCI) having a rated residual operating current not exceeding 30mA.
1. Install the pump as close to the pool as possible, preferably in a dr y, well ventilated
area away from direct sunlight. Protect the pump from excessive moisture.
2. Place the pump as close to the water source as possible, so that the suction pipe is
short, straight and direct to reduce the friction loss. Don't install the pump at more
than 10 ft (3 meters) of geometrical height from water level.
3. Before installing the pump, make sure that the surface is solid, elevated, rigid and
vibration free.
If the RCD / GFCI device trips, it means there is fault on the power line
or motor. Do not use this pump. Disconnect the pump and have the
problem corrected by a qualified ser vice representative before using.
Press the reset button to reset the RDC / GFCI devices after fixed. It will
keeps the circuit shut off and will not reset if the power line problem is
not fixed.
It is recommend to test the RCD / GFCI at least once a month.
Pumps should be shipped with Power cord with plug for corresponding countries. If there
is not power cord attached to the pump, it is necessar y to follow the local electricity
power line color code to connect the power according to the wiring for individual pump
diagram.
Bonding Instructions – Permanently wired units will need to include instructions for
connecting the solid copper, equipotential bonding conductor. For SDUS050, SDUS075,
SDUS100, SDUS150, STUS050 and STUS075 with ETL Mark for the United States, the size
of the bonding conductor should be No. 8 AWG. For Canada the size of the bonding
conductor should be No. 6 AWG. Bonding Nut location is as photo.