background image

P9    START UP

ROUTINE MAINTENANCE   P10

6. START UP

1. Never run pump dr y! Running pump dr y may cause damage to

the mechanical seal causing leakage and flooding. Fill the pre-filter 

with water before starting motor.

2. Before removing the pre-filter Lid, STOP PUMP, CLOSE GATE

VALVES in suction and discharge pipes.

3. Always STOP THE PUMP before when RELEASE ALL PRESSURE from the pump and the 

piping system before proceeding.

4. Never tighten or loosen screw while the pump is in operation.

5. The suction pipe and the suction inlet in the pool must be free from obstruction.

Before start-up, the alignment of the pump should be checked. The tubing should be 
inspected to ensure that they are properly fitted and tightened and that they do not 
exert  pressure  or  tension  on  the  pump's  suction  or  discharge  connection.  The  pump 
should never be operated.

Tighten/untighten the pump Lid by hand only. 

7. ROUTINE MAINTENANCE

The pump mechanical seal requires no lubrication and ser vice.

The  only  routine  maintenance  needed  is  the  inspection  and  cleaning  of  the  pre-filter 
basket. Debris or trash collected in the basket will choke off the water flow through the 
pump. Follow the instructions below in order to clean the pre-filter basket:

Turn  off  the  pump,  close  the  gate  valve  in  suction  and  discharge,  and  release  all 
pressure from the system before proceeding.

For SD pump series, turn the transparent Lid cover follow the arrow on the Lid cover by 

opening key provided to   release and lock the Lid ring. 

For SDUS pump series, place the key for Lid around the transparent Lid cover, hold the 

two handles and turn anti clockwise to release the Lid. 

Remove  the  pre-filter  basket  and  cleaning.  Make  sure  all  the  holes  in  the  basket  are 

clear,  flush  the  basket  with  water  and  replace  it  in  the  trap  with  large  opening  at  the 
pipe connection port (between ribs provided). If the basket is replaced backwards, the 
cover will not fit on the trap body.

Clean and inspect the Lid's O-ring ring; reinstall on the Lid cover.

Clean the ring groove on the pre-filter body and replace the Lid. To help keep the Lid 

from sticking, tighten it by hand only.

Put back the basket in 90 degree orientation of the center line properly.

Fill up the filter body with water and Prime the pump.

1. 

2. 

3. 

4. 

5. 

6. 

7.  

8. 

1.  Clear  all  piping  of  construction  debris  and  verify  that  the  piping  has  passed  a  proper 

pressure test.

2.  Check  the  filter  and  other  equipment  for  proper  installation,  verifying  all  clamps  and 

connections are properly installed as per the manufacturer's instructions.

3. Open any shut off valves on the suction and discharge lines.

4. Open the filter pressure relief valve and release all pressure from the system.

5.  If  the  pump  is  located  below  the  water  level  of  the  pool,  opening  the  pressure  relief 

valve will fill the pump with water.

6.  If  the  pump  is  located  above  the  pool  water  level,  remove  the  Lid  from  the  pre-filter 

and fill with water before starting the pump.

7. Check to see that the Lid O-ring and seat areas are clean and lubricated. Debris in the 

sealing  area  can  cause  air  to  leak  into  the  system  and  make  it  difficult  to  prime  the 
pump.

8. Close/tighten the Lid to make an airtight seal.

9. 

10. 

Turn on the pump.

If  the  pump  does  not  prime  within  15  minutes.  Ensure  all  instructions  to  this  point 

have  been  followed.  Stop  the  pump!    Check  for  suction  leaks  and  repeat  steps  (I) 
through (VIII). 

SD

 

series

 

SDUS

 

Series

Basket handle

 

position

 

 

8.

 

WINTERIZING

If  the  air  temperature  drops  below  0°C  (35°F),  the  water  in  the  system  can  freeze  and 
cause damage. Freezing damage is not warrantable.

To prevent freezing damage follow the procedures listed below:

1. Shut off electrical power for the pump at the house circuit breaker.

2. Drain the water out of the pump case by removing the two drain plugs from the case.

3. Store the plugs in the pump basket.

4. Cover the motor to protect it from severe rain, snow and ice.

5. If it is possible, store the pump in a dr y location during this time.

6. Do not wrap the motor in plastic. It will cause condensation and rust on the inside of 

the motor.

Summary of Contents for 88020203

Page 1: ...EMAUX WATER TECHNOLOGY CO LTD STRIVE FOR CLEAR WATER www emauxgroup com USER MANUAL Model SD ST Series SAA gepr fte Sicherheit SD SDUS Series ST STUS Series Swimming pool pump EMPU21070543...

Page 2: ...he voltage should be referred to the individual pump operation voltage 6 The pump is capable of high flow rates use caution when installing and programming to limit pumps performance only 7 Switch OFF...

Page 3: ...Baker VGB Pool and Spa Safety Act 1 Body Entrapment a section of the torso becomes entrapped 2 Limb Entrapment an arm or leg is caught by or pulled into an open drainpipe 3 Hair Entrapment or entangl...

Page 4: ...8023203 88023204 88023205 88023206 Code 115V 60Hz 20 F 24 F 30 F 40 F 60 F 60 F 88020203 88020204 P5 PRODUCT INFORMATION ST STUS P6 88022101 88022102 88022103 88022104 88022105 88022106 Code 220V 50Hz...

Page 5: ...rainage is adequate to prevent flooding 9 Make sure that the pump and piping are accessible for servicing Note The pump suction and discharge connections are mounded in thread stops DO NOT try to scre...

Page 6: ...ody Clean and inspect the Lid s O ring ring reinstall on the Lid cover Clean the ring groove on the pre filter body and replace the Lid To help keep the Lid from sticking tighten it by hand only Put b...

Page 7: ...or windings burned out 5 Defective starting switch inside single phase motor 6 Pump Shaft rotating in wrong direction 7 Low voltage Pump does not reach full speed 1 Low voltage 2 Pump connected to the...

Page 8: ...or SS SD SQ ST033 Pump 100V Capacitor for SS SD SQ ST020 AMU020P TP 50 60Hz Capacitor for SS SD SQ ST033 Pump Cable Box for SD SQ SP ST050 120 Pump Cable Box for SQ ST SD020 033 SS020 SS030 Pump Cable...

Page 9: ...on QTY 10 10 10 10 10 10 10 10 10 10 11 12 12 12 12 12 12 12 12 12 12 13 14 15 16 16 17 17 18 89022203 89022204 89022205 89022206 89022305 89022306 89022301 89022302 89022303 89022304 89022101 0401602...

Page 10: ...egins on the day of purchase and extends only to the original purchaser It is not transferable to anyone who subsequently purchases the product from you It excludes all expendable parts During the war...

Reviews: