FAILURES
CAUSES
SOLUTIONS
By setting the switch (2) to
“1”, the water cleaner does
not start.
Remember also what
mentioned in the note of
section “Interrupting use
(Total Stop)”.
A safety device of the system to
which the water cleaner is connected
(fuse, differential switch, etc.) has
triggered.
The plug of the power supply cable is
not inserted correctly.
Reset the protection device.
In case of a new triggering, do not use
the water cleaner and apply to a Skilled
Technician.
Disconnect the plug from the socket and
reconnect it correctly.
The water cleaner vibrates a
lot and is noisy.
The water inlet filter (15) is dirty.
The water supply is not enough.
Observe what mentioned in the section
“Routine maintenance”.
Check that the tap is completely opened
and that the capacity of the hydraulic
network conforms with what mentioned
in the section “Features and technical
specifications”.
Insufficient detergent suction.
The detergent suction control
device (22) is not correctly set.
No detergent in the bottle.
Detergent used is too thick.
Go over the paragraph “Use with
detergent”.
Add detergent
Use a detergent recommended by the
manufacturer, diluting it according to
the name plate.
No water comes out from the
nozzle.
Water missing.
Water nozzle clogged.
Check that the tap of the water network is
completely opened.
Clean and/or replace the nozzle.
The water cleaner stops
during the operation.
A safety device of the system to
which the water cleaner is connected
(fuse, differential switch, etc.) has
triggered.
The amperometric protection device
has cut in.
Reset the protection device.
In case of a new triggering, do not use
the water cleaner and apply to a Skilled
Technician.
Observe what mentioned in the section
“Safety devices”.
Rotating the main switch (2),
the motor hums but does not
start.
The electrical system and/or the
extension are not suitable.
Observe what mentioned in the section
“Checks and connection to mains
electricity supply”.
GB
Summary of Contents for IP 1400
Page 2: ...26 27 1 30 2 1 13 14 5 10 11 12 3 7 4 6 9 9 25 20 21 22 23 24 L 16 17 19 18...
Page 3: ...2 28 16 29 S 3 A B C D D E F G a b 18...
Page 71: ...71 1 1 1 1 2 1 3 1 3 1 1 3 2 EL...
Page 73: ...73 b c 29 28 16 2 S 2 3 3 3 1 1 12 10 13 EL...
Page 78: ...78 7 a 7 1 26 19 7 2 50 100...
Page 79: ...79 8 9 2 1 Total Stop 15 22 2 EL...